Johnson Controls NSB8BPN240-0 Sensor
The Johnson Controls NSB8BPN240-0 is a high-performance network humidity and temperature sensor designed for seamless integration with Metasys and Facility Explorer systems. As the direct replacement for NS-BPB7001-0, this unit features a backlit LCD fixed segment display and a 2% relative humidity accuracy rating, making it a critical component for precise environmental control on the Sensor Actuator (SA) Bus. Engineered for versatility, it supports BACnet MS/TP protocol communication and allows for absolute setpoint adjustments directly from the interface. The white enclosure is designed for both surface mount and vertical wallbox installations, providing flexible termination options via modular jacks or screw terminals. Technicians can easily toggle between Fahrenheit and Celsius scales, and the onboard screen lockout prevents unauthorized field tampering, ensuring system setpoints remain within operational parameters.
Key Benefits- System Compatibility: Fully compatible with Johnson Controls Smart Equipment, Verasys, and FX-PC series programmable controllers.
- Dual Monitoring: Integrated sensors provide simultaneous temperature and humidity monitoring with high-precision 2% RH accuracy.
- Simplified Commissioning: Features a local SA Bus access port, allowing technicians to service or commission the controller without removing the housing.
- Energy Efficiency: Supports occupancy override functions to signal controllers for temporary setpoint shifts, optimizing HVAC runtimes.
- Field Flexibility: Includes DIP switches for unique sensor addressing in multi-node averaging applications.
Is the NSB8BPN240-0 compatible with older NS series legacy systems?
Yes, this model is the direct professional replacement for the NS-BPB7001-0 and integrates with existing SA Bus architectures used in Metasys and Facility Explorer environments.
How is the sensor addressed for multiple unit installations?
This addressable network sensor utilizes onboard DIP switches to set unique device addresses (typically 200–203) when multiple sensors are required on a single bus segment.
Can the display default be changed from temperature to humidity?
Yes, the LCD fixed segment display allows for field-selectable defaults, letting the user choose between continuous viewing of zone temperature, RH, or the temperature setpoint.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.