Lennox 31Z16 Ignition Control Board
The Lennox 31Z16 ignition control board is a genuine OEM replacement component designed to manage burner ignition in compatible Lennox gas-fired heating equipment. Also identified by manufacturer part number 627562-10, this ignition control kit helps restore proper heating operation by coordinating the ignition sequence and gas valve operation.
The Lennox 627562-10 ignition control kit is listed as a replacement for several earlier ignition control part numbers, including 27P17, 15T94, 83W88, and 76W25, subject to equipment compatibility.
This Lennox furnace ignition module is suitable for servicing equipment experiencing ignition failure, intermittent burner operation, or control-related heating problems. Before replacing the board, technicians should inspect the igniter, flame sensor, gas valve, electrical connections, grounding, and applicable safety circuits.
Installing the correct OEM Lennox furnace control board helps maintain the equipment's intended ignition sequence and combustion safety functions. Verify the equipment model, serial number, original control board number, and wiring configuration before installing this gas furnace ignition control board.
Technical Specifications
|
Specification |
Details |
|---|---|
|
Manufacturer |
Lennox |
|
Catalog Number |
31Z16 |
|
Manufacturer Part Number |
627562-10 |
|
Product Type |
Ignition control board kit |
|
Component Category |
Electronic ignition control |
|
Control Function |
Burner ignition management |
|
Application |
Compatible gas-fired heating equipment |
|
Replacement Type |
Genuine OEM replacement |
|
Previous Part Numbers |
27P17, 15T94, 83W88, 76W25 |
|
Additional Cross-Reference Numbers |
103130-02, 607308-02, 607308-01 |
|
Input Voltage |
Verify equipment specifications |
|
Ignition Configuration |
Equipment-specific |
|
Mounting Configuration |
Equipment-specific |
|
Electrical Connections |
Verify original wiring configuration |
|
Gross Weight |
2 lbs |
|
Quantity |
1 ignition control kit |
Key Benefits
-
Genuine Lennox OEM component: Maintains compatibility with approved Lennox heating equipment.
-
Electronic ignition control: Coordinates burner ignition and associated gas valve operation.
-
Multiple replacement part numbers: Supports replacement of several earlier Lennox ignition control modules.
-
Heating system restoration: Addresses ignition-related heating failures caused by a defective control board.
-
Combustion safety functionality: Supports the equipment's designed ignition and safety sequence.
-
Equipment-specific design: Maintains the intended electrical and operational characteristics of compatible heating equipment.
-
Reliable burner operation: Supports proper ignition and flame-proving sequences when correctly installed.
-
HVAC service replacement: Suitable for professional repair and maintenance of compatible gas-fired heating systems.
Common Questions
What is the Lennox 31Z16 ignition control board used for?
The Lennox 31Z16 manages burner ignition and associated gas valve operation in compatible Lennox gas-fired heating equipment.
What is the manufacturer part number for the Lennox 31Z16?
The Lennox 31Z16 is identified by manufacturer part number 627562-10 and is cataloged as an ignition control kit.
What part numbers does the Lennox 31Z16 replace?
The Lennox 31Z16 is listed as a replacement for the following part numbers:
|
Previous Part Number |
Replacement Part Number |
|---|---|
|
27P17 |
31Z16 |
|
15T94 |
31Z16 |
|
83W88 |
31Z16 |
|
76W25 |
31Z16 |
|
103130-02 |
31Z16 |
|
607308-02 |
31Z16 |
|
607308-01 |
31Z16 |
Equipment model and serial number verification is recommended before substitution.
What are the symptoms of a defective Lennox ignition control board?
Common symptoms of ignition control problems include failure to ignite, intermittent burner operation, ignition lockout, failure to energize the gas valve, and a no-heat condition. Additional diagnostic testing is necessary to confirm control board failure.
Will replacing the Lennox 31Z16 fix a furnace that is not heating?
If the ignition control board is defective, replacement can restore heating operation. However, technicians should first check the ignition components, gas supply, transformer, flame sensor, pressure switches, limit switches, wiring, and grounding.
Is the Lennox 31Z16 a universal ignition control board?
No. The Lennox 31Z16 is an equipment-specific OEM replacement ignition control kit. Compatibility must be confirmed before installation.
Does the Lennox 31Z16 include an igniter or flame sensor?
The product is cataloged as an ignition control kit. Additional kit contents should be confirmed before ordering. An igniter or flame sensor should not be assumed to be included.
Can I replace the Lennox 27P17 with the 31Z16 ignition control board?
Yes, the 31Z16 is listed as a replacement for the 27P17. Verify equipment compatibility and follow the applicable manufacturer installation instructions.
What causes a Lennox ignition control board to fail?
Common causes include electrical voltage fluctuations, moisture intrusion, excessive heat, damaged wiring, poor grounding, shorted electrical components, and deterioration of internal electronic components.
What should technicians verify before ordering the Lennox 31Z16?
Technicians should verify the equipment model and serial numbers, original ignition control part number, supply voltage, ignition type, wiring harness configuration, and applicable replacement instructions.
Does the Lennox 31Z16 require professional installation?
Installation should be performed by a qualified HVAC technician. Proper wiring, grounding, ignition sequence verification, flame proving, safety circuit testing, and combustion testing are essential for safe equipment operation.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
31Z16 is the cross for 27P17, 22K51