Rheem-Ruud 61-100141-17 TXV

Rheem-Ruud 61-100141-17 TXV

  • $278.00


Ensure precise refrigerant metering with the Rheem-Ruud 61-100141-17 TXV, a critical component for maintaining peak performance in 1.5-ton HVAC systems. Specifically engineered for R-22 refrigerant, this thermostatic expansion valve regulates flow based on evaporator load, preventing liquid slugging and protecting the compressor. With a 3/8" sweat inlet and outlet, this valve provides a secure, leak-free connection essential for veteran contractors performing high-stakes repairs. The 30-inch capillary tube and 18-inch external equalizer connection (1/8" sweat O.D.) allow for accurate sensing of suction line temperatures and pressures, ensuring the system maintains a consistent superheat between 8 to 14 degrees. As a genuine Rheem OEM replacement part, the 61-100141-17 replaces legacy part numbers 61-100141-03 and 61-100141-04, offering a direct-fit solution that eliminates compatibility guesswork during technical pull-and-replace operations in residential air conditioning units. Professional installation by a licensed technician is required to verify charge levels and sensing bulb placement for optimal 1.5-ton system efficiency.

Key Benefits
  • Precise Superheat Control: Automatically adjusts refrigerant flow to match the heat load, optimizing evaporator efficiency in 1.5-ton units.
  • Compressor Protection: Actively prevents liquid refrigerant from reaching the compressor, extending the service life of the heart of the HVAC system.
  • OEM Compatibility: Designed specifically for Rheem and Ruud equipment using R-22 refrigerant, ensuring exact fit and factory-spec performance.
  • Durable Construction: High-quality brass body and stainless steel power element designed for long-term reliability in harsh operating environments.
Common Questions

Is the 61-100141-17 compatible with R-410A systems?
No, this expansion valve is specifically calibrated for R-22 refrigerant. Using it with R-410A will result in improper metering and potential system failure.

What is the purpose of the 1/8" external equalizer connection?
The external equalizer compensates for pressure drops across the evaporator coil, allowing the TXV to sense the actual pressure at the coil outlet for more accurate superheat management.

Can I use this TXV on a 2-ton or 3-ton unit?
This valve is rated for a nominal capacity of 1.5 tons. Installing it on higher tonnage units will cause the system to be "starved" of refrigerant, leading to low suction pressure and frozen coils.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question