Siemens Building Technology 599-10307 Valve
The Siemens Building Technology 599-10307 Valve is a 1/2-inch, two-way ball valve engineered for precision flow control in commercial HVACR hydronic systems. This 10 Cv ball valve features a forged brass body and is designed specifically to handle hot or chilled water, as well as glycol solutions up to 50% concentration. Utilizing a chrome-plated brass ball and a robust brass stem, this valve provides an equal percentage flow characteristic to ensure linear heat transfer across terminal units like fan coils, reheat coils, and unit conditioners. With a high 200 psi close-off pressure and an ANSI Class IV leakage rating, it delivers reliable shutoff performance under demand. The NPT female threaded connections facilitate standard pipe integration, while the blowout-proof stem increases safety in high-pressure applications. This 599 Series valve body is compatible with Siemens OpenAir actuators and includes a thermal barrier to protect the motor from extreme media temperatures, ensuring consistent operation in demanding HVAC control systems.
Key Benefits:- Precision Control: The equal percentage flow design prevents hunting in the control loop, optimizing the performance of heat exchangers.
- High Close-Off: Rated for 200 psi close-off to prevent bypass leakage even in systems with high differential pressures.
- Thermal Protection: Integrated standoffs provide a thermal barrier between the actuator and the valve body, extending electronic component life.
- Versatile Media Handling: Suitable for hydronic systems ranging from 35°F to 250°F, including high-concentration glycol mixtures.
- Manual Override: Features an operating handle for manual positioning during commissioning or in the event of power loss.
- What is the maximum pressure rating for this Siemens valve? The valve has a 600 WOG rating and an ANSI 250 body rating, with a maximum static pressure of 360 psi.
- Which actuators are compatible with the 599-10307? This body is designed to pair with Siemens GDE, GLB, GMA, and GQD series OpenAir actuators using the universal mounting plate.
- Can this valve be used for steam applications? No, this specific model is designed for water and glycol solutions; it is not rated for steam service.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.