Veris Industries PX3UXX05 Transducer
The Veris Industries PX3UXX05 differential pressure transducer is a field-selectable solution engineered for precise monitoring of air and non-aggressive gases. As the direct replacement for the PXUXX05S, this universal pressure sensor features high-accuracy ceramic capacitive sensing technology to maintain long-term stability in commercial HVAC duct static pressure applications. With seven field-selectable pressure ranges covering 0-1" WC to 0-10" WC and sub-ranges for lower pressure thresholds, the PX3UXX05 provides maximum flexibility for building automation systems (BAS). The unit supports 4-20mA, 0-5VDC, and 0-10VDC analog outputs, ensuring compatibility with virtually any controller. Designed for rugged performance, the IP65/NEMA 4 rated enclosure handles demanding mechanical room environments. Whether you are managing clean room monitoring or variable frequency drive (VFD) speed control, this dry media pressure transducer delivers the reliability required for critical airflow management and filter status monitoring.
Key Benefits
- Field-Selectable Versatility: Simplifies inventory by offering multiple unidirectional and bidirectional pressure ranges within a single device.
- High Stability Sensing: Utilizes a ceramic capacitive element to minimize drift and ensure accurate low-pressure sensing.
- Direct Replacement Logic: Specifically designed to replace the legacy PXUXX05S with improved electronics and housing.
- Simple Installation: Tool-less range selection and jumper-configurable outputs streamline commissioning on the job site.
- Dual Display Options: Features an integrated LCD for immediate local pressure readings and troubleshooting.
Common Questions
How do I change the output signal from voltage to current?
The PX3UXX05 utilizes internal jumpers to toggle between 4-20mA and volts. Always ensure your controller configuration matches the hardware jumper setting before powering the 24VAC/DC circuit.
Can this sensor be used for water or liquid pressure?
No, the PX3UXX05 is a dry media transducer intended for air or non-conductive gases only. For hydronic systems, a wet-to-wet differential pressure sensor is required.
What is the best way to calibrate the unit in the field?
The device features a push-button auto-zero function. Ensure there is no pressure on the ports (open to atmosphere) before holding the zero button to reset the baseline.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.