Veris Industries TFCIR00 Temp Sensor

Veris Industries TFCIR00 Temp Sensor

Veris Industries

  • $74.00


The Veris Industries TFCIR00 is a trade-grade duct mount temperature sensor engineered for precise thermal monitoring within commercial building automation systems. Built with a 6-inch corrosion-resistant stainless steel probe, this unit provides reliable data for air handlers and terminal units without the drift associated with lower-quality components. It utilizes a 1k Ohm Balco RTD (Nickel-Iron) element, delivering a positive temperature coefficient (PTC) for high-accuracy resistive output compatible with most major BAS controllers. The assembly includes a rugged galvanized steel handi-box enclosure with knockouts, simplifying HVAC duct sensor installation for field technicians. With an operating range of -13 to 221 °F, the TFCIR00 is a versatile solution for return, discharge, and mixed air sensing. The factory pre-calibrated RTD ensures stable temperature measurement immediately upon deployment, eliminating the need for time-consuming field calibration. This sensor is the standard choice for contractors requiring a durable, low-maintenance duct probe for indoor air distribution applications.

Key Benefits
  • High-Accuracy RTD: The 1k Ohm Balco element provides consistent, repeatable resistance-to-temperature tracking across a wide operating range.
  • Rugged Construction: Features a durable 6" stainless steel probe and a galvanized steel mounting box for protection in high-velocity duct environments.
  • Ease of Installation: Standard 22 AWG pigtail wiring and circular knockouts allow for rapid connection to 2-wire resistive circuits.
  • Wide Compatibility: Designed to interface seamlessly with building management systems from Siemens, Honeywell, and Johnson Controls that support Balco curves.
Common Questions
  • Does this sensor require field calibration? No, the TFCIR00 is factory pre-calibrated to maintain high accuracy without manual adjustment at the time of installation.
  • Is this sensor suitable for outdoor or wet environments? This specific model is designed for indoor duct applications and should not be used in locations exposed to direct moisture or outdoor weather conditions.
  • What is the resistance curve for this sensor? The TFCIR00 uses a 1k Ohm Balco curve, common in legacy and modern HVAC control systems requiring a Nickel-Iron PTC element.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question