Weil McLain 383-500-355 Air Silencer
The Weil McLain 383-500-355 Air Silencer is the OEM air inlet silencer for the Ultra 310 gas boiler. On the Ultra boilers the air inlet silencer sits in the combustion air path ahead of the blower. Its job is to smooth and quiet the air as it is drawn toward the blower, so the boiler runs without the whooshing and whistling that an open intake would produce.
The Weil-McLain Ultra manual describes the air inlet silencer as part of the combustion air path. A silencer that has cracked, shifted, collapsed or lost its gasket seal causes problems you can hear and measure: more intake noise, a whistle at high fire, air leaking in around the joint, or an unsteady air flow to the blower that makes the boiler lighting and modulation less stable. Because the silencer sits in the incoming air path ahead of the blower, it also has to stay clean and tight so the burner gets a steady supply of air for the air-fuel ratio. This is a part that gets inspected whenever the cover is off for annual service of the Ultra.
Fitting is simple but should be done with power and gas off. Remove the old silencer, check the connection at the blower inlet and the air intake side for damage or buildup, fit the new silencer with a good seal at every connection, and make sure it is seated fully and not pinched against the cabinet. After the boiler is reassembled, run a complete heat cycle and listen for any air noise or leaks at the joints, then confirm combustion readings with an analyzer. Confirm the boiler is an Ultra 310 on the rating plate before ordering, since the part is matched to the boiler size.
Key Benefits
- OEM Air Silencer: The 383-500-355 is the Weil-McLain factory air inlet silencer for the Ultra 310.
- Quieter Intake: Smooths and quiets the combustion air on its way to the blower.
- Steady Air Supply: A clean, sealed silencer keeps the air flow stable for the air-fuel ratio the control expects.
- Matched To The Boiler: The 383-500-355 is specified for the Ultra 310, so confirm the model before ordering.
Common Questions
- Which boiler is this silencer for? The Weil-McLain Ultra 310. Confirm the model on the rating plate before ordering.
- What does an air silencer do? It quiets and smooths the combustion air as it is drawn into the blower.
- What happens if it is damaged? You may notice more intake noise, air leaks at the joints or unsteady air flow to the blower.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.