Weil McLain 450-021-244 Draft Hood

Weil McLain 450-021-244 Draft Hood

Weil McLain

  • $290.00


The Weil McLain 450-021-244 Draft Hood is the vertical draft hood for size 6 boilers in the Weil McLain CG gas family, shown as the CG(m)-6 hood and on the CGa-6 parts breakdown. Atmospheric gas boilers rely on natural draft, and the draft hood is the component that keeps that draft from bossing the burners around. Its open skirt pulls room air into the vent along with the flue products, evening out strong chimney pull and giving a backdraft an escape path that does not run through the flame.

The assembly is a complete sheet metal hood with a crimped top collar for the vent connector, a conical shoulder, a wide open skirt and a long lower pipe that serves as the inlet from the boiler. The skirt carries a stamped notice that the draft hood must be installed without alteration, along with a clearance instruction relating to the boiler jacket. Read the markings on the new part and the boiler manual together, and set the hood exactly where they put it. The size 5 hood, 450-021-243, is a separate number, so verify the boiler size before ordering.

Draft hoods usually need replacement because of rust, pinholes, physical damage or an earlier modification that never should have been made. Moisture damage is a clue worth following: look at the chimney size and condition, short cycling, low water temperatures and any exhaust fans that might be depressurizing the room. With the boiler off and cool, support the vent, remove the damaged hood and install the replacement without trimming or bending it. Fasten the vent joints, restore the clearance and fire the boiler. Check at the skirt for spillage once the chimney has warmed, then confirm that the flame stays steady and combustion readings are acceptable.

Key Benefits

  • Draft Stabilization: Dilution air through the skirt softens chimney pull and downdrafts so the burners see more consistent conditions.
  • Size Specific Fit: 450-021-244 is identified for size 6, including CG(m)-6, which keeps it distinct from the adjacent hood sizes.
  • Complete Hood Assembly: Collar, hood body and inlet pipe come together as one assembly, so there is no field fabrication at a safety critical point.
  • Marked Installation Notice: The stamped instruction against alteration reminds every installer that the hood geometry is part of the boiler venting design.

Common Questions

  • Which boiler does the 450-021-244 hood fit? It is the vertical draft hood for CG(m)-6 and is shown for the CGa-6. Match the rating label model and series before ordering.
  • Is it interchangeable with the size 5 or size 7 hoods? No. Size 5 uses 450-021-243 and size 7 uses 450-021-245. Installing the wrong hood can upset draft.
  • Why did my old draft hood rust out? Common causes include flue gas condensing in an oversized or cold chimney, short run cycles, spillage and damp or chemically contaminated boiler room air. Correct the cause when you replace the hood.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.