Weil McLain 510-312-176 Draft Inducer Assembly

Weil McLain 450-021-245 Draft Hood

Weil McLain

  • $383.00


The Weil McLain 450-021-245 Draft Hood is the vertical draft hood for size 7 boilers in the Weil McLain CG gas family, identified as the CG(m)-7 hood and shown for the CGa-7. The draft hood sits between a natural draft boiler and its vent connector and performs a job that is easy to take for granted. Through its open skirt it admits dilution air, which moderates chimney suction and relieves downdrafts before they can disturb burner operation or smother the flame.

As the larger boiler sizes move more flue gas, matching the hood to the size becomes especially important. An undersized hood can spill combustion products into the room, while the wrong geometry can change how the vent behaves. Order 450-021-245 for size 7 equipment. The neighboring 450-021-244 serves size 6, and the two are separate parts even though they perform the same function. Compare the replacement with the original for collar size, hood body and inlet length, and follow the markings on the part and the boiler installation manual for positioning and clearance.

Inspect an existing hood at every annual service. Rust scale, holes, dents that restrict the passage, loose vent joints and scorch marks around the jacket all deserve attention. Soot or heat staining may mean the boiler has been spilling, so check the chimney, vent connector, combustion air supply and heat exchanger passages before simply swapping metal. To replace the part, turn off the appliance, allow it to cool, support the vent piping and remove the old hood. Install the new one unmodified, secure the connections as code requires, and prove proper venting with the boiler running and any exhaust appliances in the building operating.

Key Benefits

  • Matched to Size 7: 450-021-245 is identified for CG(m)-7 boilers, supporting a correct venting repair on the larger size.
  • Protects Flame Stability: The open skirt relieves downdrafts and excess pull so burner performance depends less on changing chimney conditions.
  • Factory Style Geometry: Using the specified hood avoids home built transitions that alter dilution air and vent behavior.
  • Straightforward Swap: A complete vertical hood replaces a corroded or damaged one without cutting and patching sheet metal in the field.

Common Questions

  • What boiler takes the 450-021-245 draft hood? It is for the size 7 boiler, identified as CG(m)-7 and shown for the CGa-7. Check the model and series on the rating label.
  • Can a draft hood be left off if the chimney draws well? No. The hood is a required part of the boiler venting system. Removing or bypassing it creates an unsafe condition and can disturb combustion.
  • What should be checked after installation? Confirm clearances and secure joints, then fire the boiler and check the skirt for spillage after warmup. Verify combustion and draft with proper instruments.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.