York S1-024-41162-000 Circuit Breaker

York S1-024-41162-000 Circuit Breaker

  • $389.00


The York S1-024-41162-000 is a heavy-duty, 3-pole circuit breaker engineered for demanding HVACR applications requiring a reliable 35 amp 240V overcurrent protection solution. Designed to meet precise OEM specifications for York, Johnson Controls, and Unitary Products, this industrial-grade breaker ensures circuit integrity under high-cycling compressor loads and blower motor startup surges. Its three-pole configuration allows for synchronized disconnection of all ungrounded conductors, preventing single-phasing events that can lead to motor burnout in three-phase equipment. Field technicians will appreciate the robust terminal lugs designed for secure high-torque wire landing. This HVAC replacement part is essential for maintaining the electrical safety and operational uptime of commercial rooftop units and split systems. By installing this genuine OEM York circuit breaker, you ensure full compatibility with existing panel busbars and maintain the UL listing integrity of the original equipment while providing superior short-circuit protection.

Key Benefits
  • 3-Pole Protection: Simultaneous trip functionality ensures all three phases are disconnected during a fault, protecting downstream motors.
  • OEM Compatibility: Specifically calibrated for York and Johnson Controls equipment to ensure correct trip curves and mechanical fit.
  • High Thermal Stability: Engineered to withstand the elevated ambient temperatures found in outdoor electrical enclosures.
  • Secure Terminals: High-quality pressure plates allow for consistent electrical contact and reduced resistance.
Common Questions

Is the S1-024-41162-000 suitable for 208V systems?
Yes, this 240V rated breaker is fully compatible with 208V three-phase systems commonly found in commercial HVAC installations.

What causes a 35 amp breaker to trip on a 3-pole circuit?
Tripping typically indicates an overcurrent condition, a grounded winding in the compressor, or a phase-to-phase short. Always verify amperage draw with a clamp meter before resetting.

Can this breaker replace a higher-amperage 3-pole breaker in a York unit?
No, you must never down-size a breaker below the Minimum Circuit Ampacity (MCA) listed on any HVAC equipment nameplate, as this will lead to nuisance tripping.