York S1-029-20482-000 Gas Burner
The York S1-029-20482-000 Gas Burner is the direct OEM replacement component designed for precision performance in York, Luxaire, and Coleman furnace assemblies. As a professional-grade furnace manifold burner, this part is engineered to exacting tolerances to ensure proper gas-to-air mixture and flame stability across the heat exchanger. When diagnosing delayed ignition or resonance issues, inspecting the HVAC burner tube for oxidation or port clogging is essential. This main gas burner features durable construction to withstand high-temperature cycling while preventing common failure points such as uneven flame distribution or rollout. Integrating this York replacement gas burner ensures the combustion sequence remains within manufacturer parameters, maintaining the system's operational efficiency. For contractors, this furnace combustion component offers a drop-in fit, eliminating the need for manifold modifications during field service. Ensure you verify manifold pressure and carry out a combustion analysis after installation to confirm this burner is firing correctly within the unit's specific BTU requirements.
Key Benefits for Contractors
- OEM Precision: Guaranteed compatibility with specific York, Coleman, and Luxaire gas furnaces for seamless installation.
- Enhanced Flame Stability: Engineered porting design ensures a consistent flame pattern, reducing soot buildup and heat exchanger stress.
- Durable Material Composition: Constructed to resist thermal fatigue and corrosion common in high-moisture combustion environments.
- Reliable Ignition: Facilitates smooth carry-over ignition across the entire burner rack to prevent hard starts.
Common Questions
Is the York S1-029-20482-000 compatible with both Natural Gas and Propane (LP) systems?
Yes, this burner tube is compatible with both fuel types; however, you must ensure the correct orifice size is utilized based on the fuel source and manifold pressure settings.
Should I replace all burners at the same time?
While burners can be replaced individually, technicians typically recommend inspecting the entire rack. If one burner shows signs of heavy oxidation or pitting, the others are likely in a similar condition and should be replaced to ensure uniform combustion.
What causes these burner tubes to fail or rust prematurely?
Burner degradation is often caused by high humidity in the mechanical room, improper venting, or secondary heat exchanger leaks in high-efficiency furnaces that allow condensate to drip onto the burner assembly.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
QUESTIONS & ANSWERS
Ask a Question-
Will this fit a York TG9S080?
Yes, it will fit.
-
Will burner Number 02920482000 interchange with burner number 02920442000? My furnace model number is P2DD12NO7601A it's a York furnace.
The closest model number that we reference is a P2UDD12N07601A. The burners for it are the S1-029-20411-700, which is obsolete without a replacement.
-
Will this fir model number p2cdd12no7601a
The burner for P2CDD12N07601A per the breakdown is the following.
4
PCS
BURNER,NATURAL GAS,MAIN
York marks it as obsolete, with no replacement.
-
Will it fit York LP GY9S080B
We need the completed model and serial numbers off the unit to check.
-
This will fit gy9s080b12up11g
Yes, it does.