York S1-024-25329-706 Pressure Switch

York S1-024-25329-706 Pressure Switch

York

  • $139.00


The York S1-024-25329-706 Pressure Switch is a mission-critical safety component designed for precise monitoring of pressure differentials within residential and light commercial HVAC systems. This SPNO (Single Pole Normally Open) switch is factory-calibrated to a 1.6" WC setpoint, specifically engineered to close on fall. This ensures that the furnace inducer motor provides sufficient draft for safe combustion before allowing the ignition sequence to proceed. As a genuine OEM York replacement part, it ensures direct physical and electrical compatibility with specifically matched furnace cabinets, eliminating the risks associated with universal "one-size-fits-all" pressure switches. The durable diaphragm construction and corrosion-resistant housing are designed to withstand high-cycle operations in demanding environments. Technicians should verify water column (WC) ratings and mounting orientation during installation to ensure a proper seal and accurate draft pressure sensing, maintaining the integrity of the furnace safety circuit and preventing intermittent lockouts or inducer motor performance issues.

Technical Key Benefits:
  • Precision Calibration: Factory-set at 1.6" WC for exact draft pressure verification.
  • OEM Integrity: Dedicated York S1-024-25329-706 specifications ensure exact terminal alignment and mounting footprint.
  • SPNO Logic: Reliable close-on-fall mechanism ensures the system only fires under optimal venting conditions.
  • Enhanced Durability: Engineered to handle the thermal fluctuations and moisture typical of high-efficiency condensing furnaces.
Common Technician Questions:

What causes a pressure switch fault code on a York furnace?
A lockout is typically triggered by a restricted vent pipe, a failing inducer motor, clogged condensate drains, or a ruptured diaphragm within the S1-024-25329-706 itself.

Can I adjust the setpoint on this pressure switch?
No. This is a factory-calibrated fixed pressure switch. Attempting to adjust the 1.6" WC setting will compromise equipment safety and void the technical certification of the furnace.

Is the S1-024-25329-706 compatible with other brands?
While it may fit some Luxaire or Coleman units sharing the same Source 1 platform, always cross-reference the OEM part number against the specific model serial plate to ensure proper pressure differential response.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question