York S1-025-41313-000 Rollout Switch

York S1-025-41313-000 Rollout Switch

York

  • $31.00


The York S1-025-41313-000 Rollout Switch is a critical safety component designed for precise thermal monitoring within York furnace gas burner assemblies. This Single Pole Single Throw (SPST) flame rollout sensor is engineered to interrupt the heating circuit when it detects excessive temperatures, preventing hazardous conditions resulting from a cracked heat exchanger or blocked flue. With a 290-degree F open temperature and a 210-degree F close temperature, this switch ensures that the system fails safe long before internal components reach critical thermal instability. As a genuine York OEM replacement part, it guarantees exact form-fit-functionality for contractors performing high-stakes repairs on residential and commercial furnaces.

When diagnosing a tripped rollout limit switch, experienced technicians recognize that an open circuit often points to underlying HVAC combustion airflow issues. The York S1-025-41313-000 provides the reliable, factory-calibrated response necessary to protect the unit's cabinet and surrounding structure. Integrating this specific HVAC high-limit safety control ensures that your repair meets original manufacturing specifications for York, Coleman, and Luxaire gas furnaces. Skip the aftermarket alternatives and rely on the thermal precision of a factory-rated S1-025-41313-000 limit switch to maintain system integrity and prevent repeated call-backs due to drifting calibration in the burner box.

Key Benefits
  • Precise Thermal Calibration: Features a factory-set 290°F open and 210°F close range to ensure consistent furnace safety shut-off during flame rollout events.
  • Direct OEM Compatibility: Specifically designed for York gas furnaces, eliminating the need for mounting modifications or terminal adjustments.
  • Durable SPST Construction: Built with robust materials to withstand the high-temperature environment of the combustion chamber.
  • System Protection: Acts as a primary defense against cracked heat exchanger hazards and backdrafting, protecting both equipment and property.
Common Questions

What causes a York rollout switch to trip repeatedly?
Repeated tripping usually indicates a significant venting obstruction, such as a blocked flue or bird's nest, or more seriously, a cracked heat exchanger. Always inspect the heat exchanger with a camera and check gas pressure settings before assuming the switch itself is faulty.

Can I bypass the S1-025-41313-000 for testing purposes?
Under no circumstances should a flame rollout switch be bypassed in a permanent installation. For temporary diagnostic continuity testing, use a multimeter to check for resistance. If the switch remains open at room temperature, it has reached its thermal limit and must be replaced.

Is this switch a manual or automatic reset?
The S1-025-41313-000 is typically a manual reset rollout switch. This design requires a technician to physically inspect the burner compartment and reset the small button on the back of the part, ensuring the root cause of the overheat is addressed before the system resumes operation.