Lennox 72F83 Sequencer Relay

Lennox 72F83 Sequencer Relay

Lennox

  • $92.77


The Lennox 72F83 Sequencer Relay is a critical 24V normally open (NO) replacement component designed for heavy-duty HVAC staged electric heat applications. As a direct OEM replacement for the Lennox 72F8301, this stacked thermal time delay relay ensures precise sequencing of furnace heating elements and blower motors to prevent electrical surges and optimize system performance. Built to withstand the rigorous demands of residential and commercial air handlers, the 72F83 utilizes a PTC (positive temperature coefficient) heater to actuate a bimetal disc, providing a reliable delay-on and delay-off cycle. This thermal sequencer features a timing range of 1-110 seconds for both "on" and "off" functions, allowing for the staggered activation of heat strips that protects the circuit breaker from in-rush current. For service technicians, the DPST configuration and standard quick-connect terminals simplify field installation, ensuring your electric furnace sequencer restoration is both efficient and up to factory specifications.

Key Benefits for HVAC Professionals:
  • Direct OEM Compatibility: Identical performance and footprint to the Lennox 72F8301, making it a drop-in solution for specific Lennox 12L63 and ECB series air handlers.
  • In-Rush Current Protection: Staged electric heat sequencing prevents simultaneous element activation, reducing the risk of tripped breakers and component fatigue.
  • Versatile 24V Control: Designed for standard low-voltage heating circuits with a normally open contact state that only closes upon a call for heat.
  • Thermal Stability: The thermal time delay relay design remains stable across a wide range of ambient temperatures, ensuring consistent switching 50/60Hz operations.
Common Questions Answered:
  • Can I use the 72F83 to replace a 72F8301? Yes, the 72F83 is the identical part to the 72F8301 and is the recommended service replacement.
  • Why are my heat strips staying on or not turning on at all? This often indicates a failed sequencer relay where the bimetal disc has warped or the PTC heater has Open-Circuited, requiring a full component swap.
  • Does this relay control the blower motor? Yes, in many Lennox HVAC systems, the first stage of the sequencer is wired to the fan circuit to ensure airflow before the heating elements reach peak temperature.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.