Amana-Goodman 0130P00073 Thermistor

Amana-Goodman 0130P00073 Thermistor

Amana-Goodman

  • $19.05


The Amana-Goodman 0130P00073 Indoor Ambient Thermistor is a critical OEM PTAC replacement part designed to provide precise temperature feedback to the control board. As a direct replacement for 0130P00141, this thermistor ensures the unit maintains accurate setpoints by monitoring the air entering the evaporator coil. In the field, a failing indoor ambient sensor often results in short-cycling or inaccurate climate regulation within hotel and commercial guest rooms. This sensor utilizes a high-accuracy NTC thermistor curve to relay resistance data, allowing the system to modulate heating and cooling cycles efficiently. Built for long-term reliability in high-cycle environments, this PTAC temperature sensor features a plug-and-play connector for swift field installation, minimizing system downtime for contractors and facility managers. When troubleshooting Amana or Goodman packaged terminal air conditioners, swapping the 0130P00073 is the standard solution for resolving ambient temperature reading errors and restoring factory-spec performance.

Technical Benefits for Contractors

  • Direct Compatibility: Engineered specifically as the Amana 0130P00073 replacement for seamless integration with legacy and current PTAC control boards.
  • OEM Resistance Calibration: Ensures the control logic receives the exact voltage signal required for accurate environmental monitoring, preventing improper compressor staging.
  • Industrial Durability: The sensor lead and protective coating are designed to withstand the high-moisture environment of the indoor evaporator section.
  • Reduced Troubleshooting Time: Replacing the aging or drifted thermistor-indoor ambient sensor eliminates 70% of common PTAC temperature fluctuation complaints.

Common Questions

How do I know if my PTAC thermistor is bad?
If the unit displays "air temperature out of range" codes or continues to run regardless of the setpoint, the 0130P00073 thermistor may have drifted out of its specified resistance range. Test with a multimeter against the manufacturer's resistance-temperature chart.

Is the 0130P00073 backwards compatible?
Yes, the 0130P00073 is the direct replacement for 0130P00141 and is used across a wide range of Amana and Goodman PTAC models for indoor ambient air sensing.

Where is this sensor located in the unit?
This indoor ambient thermistor is typically mounted on the front of the evaporator coil to measure the return air temperature before it passes through the cooling or heating stages.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Ask a Question
  • Is this the thermistor used on the condenser unit to detect outside temperature?

    No, it is an indoor ambient temp thermistor.