Heil Quaker ICP 1013102 Rollout Switch
The Heil Quaker ICP 1013102 Rollout Switch is a critical safety component engineered for International Comfort Products gas-fired furnaces. This single pole single throw (SPST) switch is calibrated to a 300 degree F fixed temperature set point to detect flame rollout or excessive heat buildup near the burner assembly. As a manual reset limit switch, it requires technician intervention to investigate the root cause of the trip—often draft issues, blocked heat exchangers, or gas pressure imbalances—before system operation can resume. This genuine OEM replacement ensures precise mechanical alignment and electrical compatibility for Heil, Quaker, and Tempstar units, including common models like the C8DNL050B12A1 and C8DNL050B12B2. Replacing a failed switch with this ICP furnace safety part provides the exact thermal response curve required by the factory to prevent cabinet damage and ensure safe combustion cycles.
Key Benefits
- Factory Calibrated Precision: Fixed 300°F trip temperature prevents nuisance tripping while maintaining strict safety overhead.
- Manual Reset Mechanism: Ensures the heating system cannot automatically restart until a potential burner malfunction is inspected.
- High-Temperature Durability: Specifically designed to withstand the thermal environment of the burner vestibule without drift.
- OEM Compatibility: Drop-in replacement for ICP part number 1013102, featuring standard 1/4-inch spade terminals for secure wiring.
- Broad Application: Verified fit for various International Comfort Products high-efficiency and standard-efficiency gas furnaces.
Common Questions
Can I bypass the manual reset on the 1013102 switch?
No. This rollout switch is a primary safety device. Bypassing or using an automatic reset switch in place of this manual reset component creates a severe fire hazard and violates code compliance.
What causes a 300 degree F rollout switch to trip?
Tripping usually indicates flame rollout, which can be caused by a cracked heat exchanger, soot buildup in the flue, or a blocked vent pipe. The manual reset allows you to verify these conditions are corrected before restoring heat.
Are the terminals on the Heil 1013102 directional?
Since this is a SPST (Single Pole, Single Throw) configuration essentially serving as a thermal fuse link, the wiring is not polarity sensitive, but secure connections to the furnace control circuit are mandatory.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.