York 025-29583-002 Transducer

York 025-29583-002 Transducer

York

  • $849.51


The York 025-29583-002 Transducer is a precision-engineered 0/125# suction transducer designed for high-accuracy pressure monitoring in industrial HVACR systems. As a critical component for chiller control loops, this York OEM replacement part provides real-time feedback to the system controller, ensuring optimal refrigerant flow and compressor protection. It serves as the direct replacement for York 025-29583-001, offering seamless backward compatibility and reliable performance in demanding environments. This transducer utilizes a reliable 4-20 mA output signal to communicate pressure data across the 0 to 125 PSI range, making it essential for maintaining HVAC system efficiency. Built to withstand the rigors of commercial mechanical rooms, the 025-29583-002 pressure sensor features a robust design that prevents signal drift and ensures long-term calibration stability. For technicians performing chiller maintenance or troubleshooting suction line feedback errors, this genuine York component is the professional standard for restoring factory-spec operational integrity.

  • Direct Replacement: Fully replaces the legacy York 025-29583-001 without requiring additional field modifications.
  • Precise Measurement: Calibrated for a 0-125 PSI range to provide accurate suction side monitoring.
  • Industrial Standard Output: Features a 4-20 mA signal for interference-resistant data transmission to the control board.
  • OEM Reliability: Genuine York construction ensures full compatibility with existing chiller microprocessor controls.
  • Durable Housing: Engineered to handle the vibration and temperature fluctuations common in heavy-duty HVACR applications.
Common Questions: Is the 025-29583-002 compatible with systems using the 025-29583-001? Yes, the 025-29583-002 is the designated direct replacement for the 025-29583-001 and provides the same fit, form, and function. What is the pressure range and signal output for this transducer? This unit is a 0/125# suction transducer that outputs a 4-20 mA signal corresponding to the detected pressure levels. Does this transducer require a specific wiring harness? It is designed to interface with standard York chiller wiring; however, always verify terminal pinouts against your specific model's wiring diagram during installation.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Ask a Question
  • 025-29583-002 is the direct replacement for 025-29583-001

    Yes, it is the direct replacement for 025-29583-001 and ready to ship.