Amana-Goodman 0130F00004 Pressure Switch

Amana-Goodman 0130F00004 Pressure Switch

Amana-Goodman

  • $81.25


The Amana-Goodman 0130F00004 Pressure Switch is a critical safety component designed for specific Goodman and Amana furnace models. This SPST (Single Pole Single Throw) vacuum switch is factory-calibrated to a -.75" WC (Water Column) set point, ensuring the induced draft motor is generating sufficient negative pressure before allowing the ignition sequence to proceed. Engineered for reliability in high-cycle environments, it features a standard 1/4" barb connection for secure pneumatic tubing attachment and 3/16" male spade terminals for electrical integration. As a direct OEM replacement part, it eliminates the calibration risks associated with universal "one-size-fits-all" switches. This HVAC inducer pressure switch is essential for diagnosing furnace pressure switch lockout codes and maintaining the operational integrity of the combustion system. Accurate manometer testing is recommended during installation to verify the venting system meets the required negative pressure thresholds for the 0130F00004 specifications.

  • Factory Calibrated: Precise -.75" WC set point ensures exact compatibility with Goodman furnace pressure switch requirements.
  • OEM Construction: High-grade diaphragm material prevents premature failure due to heat cycling and flue gas particulates.
  • Secure Pneumatic Interface: The 1/4" barb connection provides a leak-resistant seal for vacuum tubing.
  • Direct Fit: Replaces specific 0130F00004 and legacy part numbers without mechanical modification to the blower housing.

Common Questions

Why is my furnace flashing a pressure switch stuck open code?
This typically indicates the 0130F00004 is not sensing the required -.75" WC. Check for blocked vents, a failing inducer motor, or cracked vacuum tubing before replacing the switch.

Can I use a switch with a different WC rating if it looks the same?
No. Using a switch with an incorrect WC rating can result in delayed ignition or unsafe combustion levels. Always match the OEM specification of -.75" WC for this application.

Does this switch handle both positive and negative pressure?
The 0130F00004 is designed as a vacuum switch to monitor negative pressure generated by the draft inducer at the flue outlet.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.