The Amana-Goodman B1370724 Ignition Module is a critical intermittent pilot ignition control designed for 24V gas-fired furnaces and packaged units. As a direct OEM replacement for the discontinued B1370723, this module ensures precise regulation of the spark generation and flame sensing sequence. It features a 90-second lockout and a 5-minute retry interval, providing necessary safety parameters to prevent unburned gas accumulation during ignition failure. This robust Goodman furnace control board is engineered to withstand high-demand cycles, maintaining consistent communication between the thermostat and the gas valve. By integrating internal safety circuits and flame rectification technology, the B1370724 effectively monitors the pilot flame to authorize the main burner fire. Whether you are performing a routine HVAC 24V ignition repair or replacing a faulty legacy controller, this genuine part offers the exact mounting footprint and terminal configuration required for Goodman, Amana, and Janitrol systems, eliminating the need for field modifications on a gas furnace ignition module replacement.

Key Benefits for Contractors
  • Broad Compatibility: Replaces a wide range of legacy part numbers including 1370722S, 1370724S, B1370720, B1370721, B1370722, B1370723, and 1370723S.
  • Safety-First Sequence: Integrated 90-second lockout and 5-minute retry cycles protect the heat exchanger and burner assembly from unsafe conditions.
  • OEM Reliability: Built by the original manufacturer to factory specifications, ensuring the B1370724 ignition control matches the system's intended logic.
  • Simplified Service: Direct-drop fitment for various Goodman and Amana furnaces reduces labor time and prevents wiring errors in the field.
Common Questions & Troubleshooting

What does it mean if the module enters a 5-minute retry?
If the module fails to sense a flame within the 90-second window, it pauses the gas flow and waits 5 minutes before attempting the cycle again. This usually indicates a dirty flame sensor, a blocked pilot tube, or a weak spark signal.

Will this replace a hot surface ignition (HSI) board?
No, the B1370724 is an intermittent pilot igniter module. If your system uses a glowing silicon carbide or nitride igniter directly for the main burners, you will require a specific HSI control board instead.

Can I use this on other brands besides Goodman?
While designed for Goodman-family brands like Amana and Janitrol, it is also found in specific Daikin, Comfort-Aire, and GMC units. Always verify the part number on your existing board before installation.