Danfoss 060-200191 Control

Danfoss 060-200191 Control

  • $115.77


The Danfoss 060-200191 KP1 Pressure Switch is the current-generation replacement for the 060-200166, providing professional-grade low-pressure monitoring for commercial refrigeration and HVAC systems. Built for the field, this auto reset pressure control utilizes a SPDT contact function to ensure reliable compressor protection or fan cycling. It features a regulation range of -0.2 to 7.5 bar (6 inHg to 108 psig) with an adjustable differential of 0.7 to 4.0 bar (10 to 58 psi), allowing for precise setpoint calibration. The 1/4 inch flare connection ensures a leak-free mechanical interface, while the IP30-rated enclosure provides a compact footprint for tight cabinet installations. This unit is compatible with high-pressure refrigerants including R134a, R404A, R448A, R449A, and R513A. Whether you are performing a retro-fit or a new install, the 060-200191 delivers the vibration resistance and high-contact load performance required for demanding industrial environments.

Key Benefits for the Contractor
  • Direct Drop-in Replacement: Serves as the official successor to 060-200166, ensuring seamless mechanical and electrical compatibility.
  • Superior Contact Reliability: The Single Pole Double Throw (SPDT) switch design offers versatile wiring options for alarm circuits or compressor cut-outs.
  • Multi-Refrigerant Compatibility: Fully rated for modern, low-GWP refrigerants like R513A and R515B, as well as standard R404A systems.
  • Durable Construction: Engineered to withstand ambient temperatures from -13°F to 149°F, making it suitable for outdoor condenser units.
  • Precise Pressure Control: High-accuracy bellows system provides consistent trip points across the entire 108 psig range.
Common Questions & Technical Support

Is the 060-200191 compatible with older R22 systems?
Yes, this switch is compatible with a wide range of fluorinated refrigerants, including R22, provided the pressure settings are within the -0.2 to 7.5 bar range.

Does this model require a manual reset after a trip?
No, this specific KP1 model features an automatic reset function, meaning it will restore the circuit once the pressure returns to the differential setpoint.

What is the maximum working pressure for this control?
The Danfoss 060-200191 is rated for a Maximum Working Pressure (MWP) of 245 psig and a test pressure of 290 psig.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.