Danfoss 032L1214 Valve
The Danfoss 032L1214 is a professional-grade EVR 10 solenoid valve engineered for precision flow control in liquid, suction, and hot gas lines. As a normally closed (NC) 2-way valve, it features 5/8" ODF solder connections, providing a robust, leak-proof interface within high-pressure HVACR systems. This unit serves as the direct 032F1168 replacement, offering an upgraded design that supports a maximum working pressure of 655 psig (45.2 bar) and a broad medium temperature range from -40°F to 221°F.
Built with a high-durability brass body and a 10 mm orifice, this Danfoss EVR 10 valve delivers a flow coefficient (Kv) of 2.2 m³/h and a Cv value of 2.6 gal/min. It is fully compatible with a wide array of fluorinated refrigerants, including R410A, R404A, R134a, and even modern A2L flammable refrigerants like R32 and R1234yf. For contractors, the solenoid valve coil is sold separately, allowing for tailored voltage configuration to match specific field requirements without replacing the entire valve body.
- Universal Compatibility: Validated for use with HCFC, HFC, and HFO refrigerants, including low-GWP options.
- High-Pressure Tolerance: Rated for a maximum operating pressure differential (MOPD) of up to 38 bar with a 10W AC coil.
- Direct Retrofit: Seamlessly replaces legacy 032F1168 models with standard 5/8" copper solder sizes.
- Internal Tightness: Enhanced sealing materials minimize internal leakage and ensure reliable system cycling.
Common Questions Regarding the Danfoss 032L1214
Is the coil included with this valve body?
No, this is the valve body only. You must select a compatible Danfoss 13.5 mm actuator system coil separately based on your application's voltage requirements.
Can I use this for hot gas bypass applications?
Yes, the EVR 10 is rated for hot gas defrost and bypass lines, provided the medium temperature does not exceed 221°F.
Does this valve require a minimum pressure drop to open?
Yes, as a servo-operated valve, the EVR 10 requires a minimum opening differential pressure of 0.03 bar (0.44 psi) to function correctly.