Emerson Alco 060011 Filter Drier

Emerson Alco 060011 Filter Drier

  • $11.32


The Emerson Alco EK-032FM (060011) is a premium liquid line filter drier designed for high-performance moisture and acid removal in light commercial and residential HVACR refrigeration systems. Featuring a 3-cubic-inch desiccant volume with a sophisticated beaded core composition (75% molecular sieve and 25% activated alumina), this unit excels in maintaining system chemistry even with POE oils. The 1/4" Female Flare x Male Flare (SAE) connections simplify field installation by allowing direct integration without additional fittings. Rated for a maximum working pressure of 680 PSI, it is fully compatible with high-pressure refrigerants including R-410A, R-134a, and R-404A. The 20-micron internal filtration media ensures the protection of expansion valves and capillary tubes from particulate contamination. This hermetic filter drier provides high flow capacity with minimal pressure drop, preventing flash gas formation and ensuring optimal evaporator performance in critical cooling applications.

Key Benefits for Field Technicians
  • Optimal Desiccant Blend: 75/25 ratio effectively captures moisture and neutralized acid to prevent compressor motor burnout.
  • High Pressure Rating: Robust steel shell construction supports 680 PSI maximum working pressure, suitable for modern high-pressure refrigerant cycles.
  • Standardized Connections: 1/4" SAE Flare (Female/Male) allows for fast replacement in existing liquid lines without brazing.
  • Particulate Filtration: 20-micron filtration protects sensitive downstream metering devices from clogging and debris.
  • Corrosion Resistance: Durable epoxy powder paint finish protects the vessel from harsh environmental conditions and oxidation.
Common Questions & Technical Insights

Is the EK-032FM compatible with POE oil and R-410A systems?
Yes, the high proportion of molecular sieve in the Emerson EK-032FM is specifically designed to handle the hygroscopic nature of POE oils used in R-410A systems while maintaining maximum moisture capacity.

Can this filter drier be installed in either direction?
No, this is a unidirectional liquid line drier. Technicians must ensure the refrigerant flow follows the arrow stamped on the shell to utilize the internal filtration and desiccant stack correctly.

What is the primary function of the flare connection configuration?
The 1/4" Female Flare x Male Flare setup is specifically utilized to simplify the connection to components like receiver tanks or solenoids, reducing the number of potential leak points in the system.