Fireye FGPS-GML-1260 Switch
The Fireye FGPS-GML-1260 is a high-performance gas pressure switch designed specifically for low-gas pressure monitoring in commercial and industrial burner applications. This unit features a 12-60" W.C. adjustable set point range, providing precise mechanical supervision to ensure safe burner operation. Built with a NEMA 4 rated enclosure, this switch is engineered for durability in demanding environments, offering superior protection against dust and moisture. The manual reset functionality integrated into the FGPS-GML-1260 ensures that the system remains locked out following a low-pressure trip, requiring a technician's inspection before the firing sequence can resume. Utilizing a reliable diaphragm-actuated design, this FM approved and UL listed safety interlock integrates seamlessly into existing Flame Safeguard systems, providing the critical electrical break needed to prevent hazardous combustion conditions. The rugged construction and repeatable accuracy make it a standard component for technicians maintaining high-capacity boilers and process heaters.
Key Benefits- Precise Low-Pressure Monitoring: The 12-60" W.C. range allows for exact calibration to meet specific burner manifold requirements.
- Enhanced Environmental Protection: The NEMA 4 housing ensures reliable performance in mechanical rooms subject to washdowns or high humidity.
- Safe System Recovery: Manual reset logic prevents automatic recycling, ensuring that the cause of low gas pressure is addressed by a professional.
- Industrial-Grade Reliability: Designed for high-cycle duty, the internal microswitch provides a positive electrical break for safety circuit integration.
What is the purpose of the manual reset on this gas pressure switch?
The manual reset ensures that the burner cannot restart automatically after a low-pressure event, allowing the technician to verify the gas supply and regulator performance before operation continues.
Can the Fireye FGPS-GML-1260 be installed outdoors?
Yes, the NEMA 4 rated enclosure is designed to protect internal components against windblown dust and rain, making it suitable for outdoor or harsh indoor environments.
How do I calibrate the set point for this switch?
The set point is adjusted via the internal scale. Technicians should use a calibrated manometer to verify the exact trip point during commissioning to ensure it aligns with the 12-60" W.C. specifications.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.