Heil Quaker ICP 1082611 Transformer

Heil Quaker ICP 1082611 Transformer

Heil Quaker ICP

  • $97.81


The Heil Quaker ICP 1082611 Transformer is a critical OEM replacement part engineered for 208/240V primary terminal applications, precisely stepping down to a 24V secondary output. Rated at 40VA, this high-performance transformer is designed to power low-voltage control circuits, including thermostats, HVAC control boards, and ignition modules in residential and commercial systems. Built for the rigors of field service, it features a robust step-down transformer design that ensures stable 50/60 Hz frequency management across diverse environmental conditions. This unit is commonly found in International Comfort Products (ICP) equipment, including Heil, Tempstar, and Comfortmaker electric furnaces and air handlers. For technicians, the ICP 1082611 provides a direct fit for units like the APFM series, maintaining system impedance and circuit integrity without the need for field modifications. Rely on this 24V furnace transformer for consistent inductive load handling and reliable voltage regulation in high-demand HVACR applications.

Key Benefits for Technicians
  • Precise Voltage Conversion: Efficiently converts 208/240V primary power to 24V secondary for sensitive control electronics.
  • 40VA Power Rating: Provides ample volt-ampere capacity to handle multiple relays and contactors simultaneously.
  • OEM Compatibility: Exact replacement for Heil Quaker 1082611, ensuring electrical specifications match the original factory design.
  • Durable Construction: Engineered with a rolled steel frame and high-quality windings to withstand thermal stress in furnace vestibules.
  • Broad Application: Compatible with a wide range of ICP, Tempstar, and Comfortmaker air handlers and electric heating units.
Common Questions & Technical Insights

What causes a 40VA transformer to fail in an ICP unit?
Most failures occur due to a downstream short in the 24V circuit, often at the contactor coil or thermostat wiring. Always verify amp draw on the secondary side before installing the 1082611 transformer to prevent immediate burnout.

Can the 1082611 be used on 120V systems?
No, this specific model is designed for 208/240V primary input. Using this on a 120V circuit will result in insufficient secondary voltage (approximately 12V), which will not engage 24V gas valves or control boards.

Is this transformer compatible with 50Hz and 60Hz power?
Yes, the ICP 1082611 is designed to operate efficiently on both 50Hz and 60Hz cycles, making it suitable for standard North American grids and various international applications.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Ask a Question
  • I have a HEIL HVAC ground level. The heater is not engaging. The transformer in the control panel is BUZZING. Is that my problem?

    It could be but you have to check the transformer output and input voltage to be sure.