Honeywell S9200U1000 Ignition Module
The Honeywell S9200U1000 is an industry-standard universal integrated furnace control designed for professional field replacement in single stage gas heating and cooling systems. As a veteran-preferred furnace ignition module, this unit offers high-level cross-compatibility, replacing over 195 OEM controls including models from York, Lennox, and Goodman. It is engineered for 120V hot surface ignition (HSI) applications and features an EnviraCOM communications bus, allowing for advanced HVAC diagnostics and twinning capabilities when integrated with compatible thermostats like the FocusPRO or VisionPRO IAQ.
This universal ignition control provides precise timing adjustments via DIP switches, including a 30-second prepurge and selectable heat fan off delay intervals of 60, 90, 120, or 180 seconds. The Honeywell S9200U1000 utilizes a microprocessor for constant monitoring of the flame rectification circuit, pressure switches, and high-limit safety loops. With a 2-second maximum flame failure response time and three ignition trials, it ensures reliable burner operation in residential natural gas or liquid propane furnaces. The onboard 3-LED interface provides immediate visual feedback for troubleshooting furnace control board status and system faults.
Key Benefits- Broad Cross-Reference Compatibility: Direct replacement for 031-01140-001, 102077-19, 102107704, and 624591A, reducing the need to carry multiple OEM boards.
- Robust Diagnostic Interface: Three dedicated LEDs (Red for status, Amber for flame, Green for EnviraCOM) expedite the identification of pressure switch failures or limit circuit opens.
- Flexible Configuration: Keyed wire harnesses and adjustable DIP switches allow for custom HSI warmup time and fan delay settings to match specific appliance requirements.
- Advanced Communication: Features EnviraCOM for remote monitoring and local diagnostic tools, improving service efficiency for contractors.
Can the S9200U1000 replace an 80V igniter control?
Yes, when paired with a 120V hot surface igniter, this universal ignition module can successfully replace boards originally designed for 80V systems.
What happens if the flame signal is not sensed?
The module incorporates a 3-trial ignition sequence. If flame rectification is not detected after the initial trial, it will attempt two retries before entering a 60-minute soft lockout and auto-restart delay.
Does this board support cooling fan delays?
The control manages a standard induction-type circulating fan with a 5-second cool fan on delay and a selectable 0 or 60-second cool fan off delay to maximize system efficiency.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.