Johnson Controls A421AEC-01 Temperature Control

Johnson Controls A421AEC-01 Temperature Control

Johnson Controls

  • $160.08


The Johnson Controls A421AEC-01 is a high-performance single-stage electronic temperature control designed for heavy-duty HVACR applications requiring precision and environmental protection. This unit features a versatile 120/240 VAC power supply and a wide temperature control range of -40?F to 212?F (-40?C to 100?C), making it ideal for everything from walk-in freezers to boiler systems. Built with a NEMA 4X watertight enclosure, the A421AEC-01 is engineered for wash-down environments and corrosive atmospheres where standard controls fail. This model serves as the direct A419AEC-1 replacement, maintaining the same footprint while offering an improved backlit LCD and a three-button touchpad for easier SPDT relay configuration. The included A99BB-25C temperature sensor with 9-inch leads ensures immediate digital thermostat functionality. Whether you are utilizing DIN rail mount or surface mounting, this Penn A421 electronic control provides advanced features like anti-short cycle delay and sensor offset to protect compressors and optimize system cycling.

Key Benefits

  • Rugged Protection: The NEMA 4X / IP66 enclosure provides a watertight, corrosion-resistant seal for demanding industrial sites.
  • Direct Legacy Swap: Simplified A419AEC-1C cross-reference allows for rapid field upgrades without extensive rewiring.
  • Enhanced Visibility: The bright, adjustable LCD screen indicates real-time temperature, parameter settings, and relay status at a glance.
  • Configurable Settings: Includes temperature setback and restricted user modes to prevent unauthorized adjustments in commercial spaces.
  • Flexible Mounting: Native support for both surface mount and DIN rail mount configurations ensures compatibility with standard control panels.

Common Questions

How do I change the operation between heating and cooling?
The A421AEC-01 automatically determines the mode based on the user-defined On and Off setpoints. To switch modes, simply adjust the setpoints so the 'On' value is higher than 'Off' for cooling, or lower than 'Off' for heating.

Can the sensor leads be extended?
Yes, the A99 temperature sensor leads can be extended. However, to maintain accuracy, use 22 AWG or larger twisted-pair wire and keep the run as short as possible to minimize resistance-induced temperature offsets.

What does the 'SF' fault code mean?
The µSF? or 'OP' code indicates a sensor failure or open circuit. Check the wiring connections at the terminal block or verify the resistance of the A99BB-25C sensor against the manufacturer?s resistance table.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.