Johnson Controls DP140005U11D Pressure Transducer

Johnson Controls DP140005U11D Pressure Transducer

Johnson Controls

  • $186.11


The Johnson Controls DP140005U11D is a high-precision low differential pressure transducer designed for critical monitoring of air and non-ionic gases. This unit features a 0-5" wc pressure range and provides a unidirectional 0-5Vdc output signal, ensuring seamless integration with building automation systems and industrial controllers. Engineered for durability in demanding environments, the IP67-rated housing protects internal components against dust and moisture ingress. As the direct replacement for DPT2640-005D, this transducer simplifies retrofitting by utilizing a standard 1/4" push-on barb fitting process connection. With a plus/minus 0.5% accuracy rating, the DP140005U11D delivers the reliable static pressure or filter monitoring required for high-performance HVACR applications. For technicians managing Johnson Controls pressure sensors, this model offers a rugged, stable solution for maintainng precise pressure differentials in commercial air handling systems.

Key Benefits
  • High-Accuracy Performance: Delivers +/- 0.5% full-scale accuracy for precise control loop feedback.
  • Rugged Environmental Protection: The IP67 enclosure ensures reliable operation in mechanical rooms and wash-down areas.
  • Seamless System Integration: Standard 0-5Vdc output is compatible with most HVAC pressure monitoring platforms.
  • Direct Legacy Replacement: Specifically engineered to replace the DPT2640-005D without extensive piping modifications.
  • Secure Connections: 1/4" barb fittings provide a reliable seal for standard pneumatic tubing.
Common Questions

Is the DP140005U11D suitable for outdoor installation?
Yes, the IP67-rated housing provides excellent protection against water and dust, making it suitable for locations where moisture exposure is a concern.

Can this transducer measure bidirectional pressure?
No, this specific model is a unidirectional pressure transducer configured for a 0 to 5 inch water column range.

What is the standard output signal for this sensor?
This unit outputs a linear 0-5Vdc signal corresponding to the detected differential pressure.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.