Johnson Controls TE-6363P-1 Temperature Sensor

Johnson Controls TE-6363P-1 Temperature Sensor

Johnson Controls

  • $51.97


The Johnson Controls TE-6363P-1 is a professional-grade outdoor air temperature sensor designed for precise ambient monitoring in commercial HVAC systems. Featuring a 10k ohm Type II thermistor, this unit provides high-accuracy resistance output compatible with Metasys systems and most building automation controllers. The 3-inch probe is housed in a rugged, weather-resistant enclosure to protect the sensing element from solar radiation and moisture infiltration, ensuring long-term signal stability. Engineered for outdoor air mount applications, the TE-6363P-1 streamlines installation with its accessible wiring terminals and durable construction, making it a reliable choice for HVAC outdoor sensor replacement. By delivering consistent feedback to the economizer or controller, this 10k Type 2 thermistor facilitates tight control over outdoor air resets and mechanical cooling strategies, maintaining system efficiency in demanding environments.

Key Benefits:

  • Precision Monitoring: High-performance 10k ohm Type II thermistor ensures accurate outdoor air temperature readings for optimized HVAC sequencing.
  • Rugged Durability: Weatherproof enclosure designed for NEMA 3R equivalent protection against environmental exposure.
  • Universal Integration: Standardized resistance curve allows for seamless integration with BAS temperature sensors and legacy Johnson Controls hardware.
  • Efficient Installation: Compact 3-inch probe length and integrated mounting flange simplify the TE-6363P-1 installation process for field technicians.

Common Questions:

What is the resistance curve for the TE-6363P-1?
This sensor utilizes a 10k ohm Type II thermistor, which is a standard curve used across the industry for high-resolution temperature feedback in environmental controls.

Can this sensor be used for duct mounting?
The TE-6363P-1 is specifically configured for outdoor air mounting. For duct applications, the TE-6300 series offers dedicated models with appropriate mounting hardware and probe lengths.

How does this sensor handle solar loading?
The enclosure is designed to shield the thermistor from direct sunlight to prevent "false highs" in temperature readings, ensuring the controller receives an accurate ambient air value.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question