The Johnson Controls V-6135-2 is a professional-grade three-way air switching valve engineered for precise pneumatic signal management in HVACR systems. This fast-acting two-position switching mechanism is a staple for contractors managing day-night switchover, heating-cooling transitions, and enthalpy control sequences. The V-6135-2 is specifically calibrated for a switchover pressure range of 11 to 15 psig (77 to 105 kPa), ensuring clean transitions between the normally open and normally closed ports. Designed with a narrow deadband, this valve eliminates the risk of both ports being open simultaneously, maintaining system integrity during output mode shifts. The barbed fittings are compatible with 5/32" or 1/4" OD polytubing air connections, providing a secure, leak-resistant fit. Its internal design ensures the upper port remains closed until a control signal is received, while the lower port remains open under standard operating conditions. Built for field reliability, the unit includes an integral mounting bracket for versatile surface installation in any orientation.

Key Benefits
  • Precise Switchover Control: Maintains consistent performance within the 11 to 15 psig range for accurate pneumatic air switching.
  • Eliminates Signal Overlap: The technical narrow deadband design ensures that the normally closed and normally open ports never bleed into each other.
  • Universal Tubing Compatibility: Equipped with dual-sized barbed fittings to accommodate common 5/32" and 1/4" OD polytubing without additional adapters.
  • Flexible Mounting: The factory-supplied integral mounting bracket allows for quick surface mounting in space-constrained control cabinets.
Common Questions
  • What is the primary function of the V-6135-2 in a pneumatic circuit? It acts as a selector or diverter, switching air flow from one line to another based on the pilot pressure reaching the 11-15 psig threshold.
  • Can this valve be repaired in the field? No, this is a sealed switching valve unit; if it operates outside of its 11-15 psig specification, a full unit replacement is required to maintain system calibration.
  • Is there an exhaust function on this specific model? No, the V-6135 series is designed strictly for switching flow between lines and does not provide an integrated exhaust function.