KMC Controls HSO-5001 Test Leads

KMC Controls HSO-5001 Test Leads

KMC Controls

  • $39.35


The KMC Controls HSO-5001 Test Leads are essential diagnostic tools for field technicians servicing KMC pneumatic and electronic control systems. These high-precision calibration test leads are designed specifically for interfacing a digital voltmeter with the meter taps on CTE-1000, CTE-1100, and CTE-5500 series thermostats and controllers. By providing a reliable two-prong thermostat connection, the HSO-5001 allows for accurate measurement of output voltages (such as the 9.1 VDC reference or T1/T3 signal) without risking damage to sensitive terminal blocks or causing shorts during the HVAC calibration process. This accessory is a requirement for setting minimum and maximum velocity limits in VAV systems and ensuring proper communication between your room thermostat and CSP-5001/5002 series controller-actuators. Whether performing initial commissioning or routine HVAC troubleshooting, these leads offer the conductivity and secure fit necessary for critical control signal verification.

Key Benefits

  • Universal Compatibility: Engineered for seamless use with KMC CTE-1000, CTE-1100, and CTE-5500 series devices.
  • Precision Diagnostics: Facilitates accurate 0?Çô10 VDC and 9.1 VDC reference voltage measurements for VAV flow controller balancing.
  • Contractor-Grade Durability: Specifically designed to fit the narrow-clearance meter taps found on professional HVAC room thermostats.
  • Efficient Calibration: Simplifies the adjustment of minimum and maximum setpoints by providing stable test points for your volt-ohm meter.

Common Questions

Are these leads compatible with non-KMC controllers?
The HSO-5001 is purpose-built for the proprietary meter tap spacing found on KMC Controls CTE electronic thermostats. While the banana plugs fit standard meters, the probe end is optimized for KMC-specific hardware.

Do I need these leads for VAV balancing?
Yes, most KMC VAV controller calibration procedures require monitoring T1 or T3 voltages at the thermostat during adjustment; these leads provide the safest and most accurate interface for that task.

Can these leads handle high-voltage testing?
These HSO-5001 leads are designed for low-voltage signal testing (typically under 24V) within building automation systems and are not intended for line-voltage applications.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question