Ranco V2-408060-270 Reversing Valve

Ranco V2-408060-270 Reversing Valve

Ranco

  • $94.12


Upgrade your system with the Ranco V2-408060-270, a high-performance 4-way reversing valve engineered specifically for technical versatility in heat pump applications. This 2-ton reversing valve features a 1/2" suction and 3/8" discharge connection, providing a precise direct replacement for 061L121000. When replacing the older 061L121100, a new Ranco LDK series solenoid coil is required to ensure proper electrical interface and magnetic pilot activation.

Built as a reliable HVAC reversing valve for both R22 and R410A systems, this unit utilizes a slide-type mechanism with a PTFE Teflon seal to minimize pressure drop and maintain high system efficiency. The hermetically sealed brass body and copper tube construction simplify the brazing process for field technicians. It is designed to operate under the full pressure of the heat pump system, requiring a minimum pressure differential of 40 PSI for positive slider shifting. Whether you are servicing a residential split system or a unitary package unit, this heat pump reversing valve ensures consistent refrigerant flow control across a broad operating temperature range.

Key Benefits for the Technician
  • Broad Compatibility: Rated for a wide spectrum of refrigerants, including R22 and R410A, making it a versatile addition to your service truck.
  • Reduced Pressure Drop: The precision-engineered metal slide and Teflon seals optimize functionality and efficiency during the heating/cooling transition.
  • Efficient Installation: High-quality copper inlet and outlet tubes allow for clean, standard brazing techniques without specialized alloys.
  • Optimized Pilot Control: Low power consumption magnetic pilot valves reduce the electrical load on the defrost board while maintaining positive reversals.
Common Questions

Is the solenoid coil included with this valve?
No, the Ranco V2-408060-270 is sold as the valve body only. You must match the coil voltage (24V, 120V, or 240V) to the existing system requirements using the LDK series solenoid coils.

What should I check if the valve fails to shift?
Verify the solenoid coil is energized and check for the correct pressure differential. A minimum delta P is required to push the slide; if pressures are too close, the valve may hang between modes.

Does this unit replace the old Danfoss or Saginomiya valves?
Yes, this is the current industry reversing valve cross-reference for the obsolete 061L121000 and 061L121100 series, provided you verify the tonnage and coil voltage during the swap.