Reznor 150771 Vent Motor

Reznor 150771 Vent Motor

Reznor

  • $535.77


When you are dealing with a draft inducer failure on a job site, replacing the unit with a high-spec components like the Reznor 150771 Vent Motor is standard practice for restoring safety and system efficiency. This OEM replacement motor is engineered specifically for the Reznor FT250 model, providing the precise 3200 RPM required to clear combustion byproducts from the heat exchanger. Operating on a 115V single-phase circuit, this 0.095 HP venter motor features a robust design that manages high-temperature exhaust cycles without premature winding degradation. The factory-measured torque and draft inducer performance ensure that pressure switches close consistently, preventing nuisance short-cycling and safety lockouts during peak heating demand. For contractors, the exact mounting footprint and wiring harness compatibility of the 60Hz inducer motor reduce labor time while maintaining the original equipment’s airflow static pressure ratings.

Key Benefits for Technicians:
  • Precise OEM Specifications: Matches the factory 3200 RPM and 115V requirements to ensure correct air-fuel mixture and venting.
  • Direct Fit for FT250: Eliminates the need for field modifications, fitting the Reznor FT250 model housing exactly.
  • Enhanced Combustion Safety: High-performance blower wheel design effectively draws out flue gases, ensuring safe furnace ventilation.
  • Industrial-Grade Build: Designed to withstand the thermal stress of continuous industrial HVAC operation.
  • Reduced Maintenance Callbacks: Reliable motor startup helps prevent pressure switch errors and ignition failures.
Common Questions & Troubleshooting:
  • Which Reznor models is this motor compatible with? This specific part is primarily engineered for the Reznor FT250. Always verify the part number on the existing motor nameplate before installation.
  • Will this fix a furnace that ignites then immediately shuts down? If the draft inducer isn't reaching full speed, the pressure switch won't stay closed. Testing the 150771 motor for proper RPM is a logical first step in troubleshooting airflow-related lockouts.
  • Does the 150771 include the capacitor? Technical data indicates this is typically supplied as a venter motor with capacitor assembly, ensuring the motor starts under load every cycle.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question