Sterling 11J28R02098-002 Gas Valve
The Sterling 11J28R02098-002 is a professional-grade 24V intermittent pilot gas valve designed for precision fuel regulation in commercial and industrial heating systems. Engineered as a direct replacement for the Honeywell VR8200A2009, this dual-stage redundant control manages natural gas flow with a standard capacity of 150,000 BTU/hr at 1-inch pressure drop. It features a 1/2" NPT inlet and outlet configuration with a factory-set 3.5" WC outlet pressure to ensure stable combustion cycles. Designed for HVAC gas valve replacement in Sterling unit heaters, this component integrates a gas cock, pilot adjustment, and automatic shut-off into a single compact housing. The VR8200A2009 crossover ensures drop-in compatibility for technicians servicing legacy atmospheric burners. This Sterling unit heater gas valve is built to maintain tight tolerances under high-demand cycles, providing the reliable pilot ignition and main burner actuation required for critical climate control applications.
- OEM Compatibility: Serves as the designated Sterling replacement part and is functionally identical to the VR8200A2009 gas valve.
- Technical Specifications: 0.5 PSI pressure rating with a standard 1/2-inch x 1/2-inch pipe size for seamless manifold integration.
- Reliable Sequencing: Direct-acting solenoid design ensures immediate response to the 24VAC thermostat signal for efficient pilot-to-main burner transition.
- Field Adjustability: Includes accessible pressure taps for accurate manometer readings during commissioning and combustion analysis.
What are the wiring requirements for the 11J28R02098-002?
This valve operates on a standard 24V, 60Hz circuit and requires a 0.5A current draw, typically controlled via an intermittent pilot ignition module.
Can this valve be used for Propane (LP) applications?
The 11J28R02098-002 is factory-configured for Natural Gas. To use with Liquid Propane, a specific OEM conversion kit must be installed by a qualified technician.
Is the 11J28R02098-002 compatible with standing pilot systems?
No, this model is designed specifically for intermittent pilot ignition systems and does not have the thermocouple connection required for older standing pilot configurations.