Sterling HVAC 11J28R06893001 Gas Valve

Sterling HVAC 11J28R06893001 Gas Valve

Sterling HVAC

  • $302.06


When you're out in the field and a Sterling unit heater or commercial furnace is cycling on the limit or failing to prove combustion, the Sterling HVAC 11J28R06893001 Gas Valve is the standard OEM replacement to restore safe manifold pressure. This is a single-stage 24V natural gas valve designed for tight-tolerance performance in residential and light industrial gas-fired appliances. Built for reliability, this component features a tight shut-off design that prevents fuel leakage during the off-cycle, ensuring the system maintains a high safety factor and optimized combustion efficiency.

The 11J28R06893001 replacement gas valve is engineered for a compact footprint, making it ideal for the cramped vestibules of Sterling garage heaters and unit heaters where space-constrained installations are the norm. Running on a standard 24-volt actuation, this low voltage gas control integrates seamlessly with most direct spark or hot surface ignition control boards. For technicians performing a natural gas to LP conversion or vice-versa, always verify the orifice requirements and regulator spring settings to ensure the burner hits your targeted manifold WC specs.

Key Benefits:
  • OEM Compatibility: Specifically engineered as a direct-fit Sterling furnace part for consistent performance without rig-up modifications.
  • Precise Gas Metering: Delivers accurate fuel flow to maintain the proper air-fuel ratio, reducing carbon buildup on the heat exchanger.
  • Technical Resilience: Robust internal construction provides superior resistance to corrosion and typical field wear in unconditioned mechanical rooms.
  • Seamless Integration: Standardized 24V terminals ensure compatibility with most existing terminal blocks and control wiring.
Common Questions:
  • How do I test for a faulty gas valve? Verify you have 24VAC at the 24v Nat Gas Valve terminals during the ignition sequence. If voltage is present and the inlet pressure is adequate but you observe 0" WC at the manifold, the internal solenoid or regulator has likely failed.
  • Can this valve be used for Propane? This unit is factory-configured for Natural Gas. While many 11J28R06893001 units can be converted using a specific manufacturer conversion kit, always check the technical manual for the specific unit heater model before proceeding.
  • Is this valve compatible with intermittent pilot systems? This valve is designed for specific HVAC control systems. Always verify the cross-reference for your specific Sterling model number to ensure the pilot flow and main valve sequencing match your ignition module.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question