The Trane KIT17858 is a critical 24V 2-stage HSI control board designed for high-performance furnace platforms requiring precise ignition sequencing and blower motor management. This integrated furnace control manages the hot surface igniter, gas valve timing, and multi-speed inducer motors to ensure optimal combustion efficiency. Engineered as a direct OEM replacement kit, it provides seamless compatibility for technicians sourcing a Trane ignition control board to resolve intermittent lockout issues or failed microprocessors. The board features advanced self-diagnostics with LED fault codes to streamline troubleshooting on the job site. By utilizing this KIT17858 control module, contractors can restore factory-spec timing for the 2-stage heating cycle, ensuring reliable flame sensing and thermal safety across Trane and American Standard residential units. This kit replaces legacy White-Rodgers and Emerson models, maintaining strict electrical tolerances for 24VAC control circuits.

Key Benefits for Professional Installation

  • Direct Cross-Reference: Engineered to replace 50A51-405, 50A51-495, CNT2184, and D330937P01 without wiring modifications.
  • Multi-Stage Logic: Supports two-stage gas valve operation and inducer speed transitions for high-efficiency furnace applications.
  • Advanced Diagnostics: Features an onboard LED that flashes specific sequences to identify flame current issues, pressure switch failures, or limit trips.
  • Robust Build Quality: Built with high-grade relays and circuitry to handle the high-amperage demands of silicon carbide or silicon nitride igniters.

Common Contractor Questions

Is the KIT17858 compatible with variable speed blowers?
This specific Trane furnace control is designed for multi-speed PSC or fixed-speed inducer applications; always verify the wiring harness pin configuration against the existing D330937P01 or CNT2184 layout.

Can I use this to replace a single-stage control board?
No, the KIT17858 is specifically programmed for two-stage heating systems. Installing a 2-stage board into a single-stage system will result in improper sequencing and potential system lockouts.

Does this kit include the flame sensor?
This is the integrated furnace control (IFC) module only. While it monitors the flame via rectification, the physical flame sensor is a separate component often replaced concurrently during a furnace repair.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Ask a Question
  • I'm looking for a replacement Control Board for Model: 50A51-495 D330937P01 CNT2184. The Trane KIT17858 HSI Control board in the photo on your site looks quite different from the original and replacement boards. I just want to make sure that it will mount exactly the same as the White Rodger's Emerson Electric versions we have used in the past for the Trane XL 80. I can also be reached at: 408-799-9992

    While KIT17858 is listed as the replacement it seems that some wiring terminals are not the same. We suggest having a contractor replace it for you since it might not be a simple wire for wire replacement. Thank you.

  • What's the difference between a 50A51-405 and a 50A51-506. I need the -506 or direct replacement.

    50A51-506 is discontinued and the replacement retrofit kit is KIT9370. Looks like it involves more than just replacing the board. Please see instructoin manual at the link below and decide if it suits your need.
    Instruction Manual