Copeland Comfort Control (White Rodgers) F92-1008 Nat/LP Kit

Copeland Comfort Control (White Rodgers) F92-1008 Nat/LP Kit

  • $8.66


The White Rodgers F92-1008 is a professional-grade conversion kit designed specifically for 36G, 36H, and 36J series 2-stage gas valves. This natural gas to liquid propane conversion allows for precise pressure regulation adjustments necessary when transitioning between fuel sources in high-efficiency residential and light commercial furnaces. As a White Rodgers gas valve conversion kit, it ensures the burner manifold pressure is correctly calibrated for 2-stage operation, maintaining stable combustion across both low and high heat cycles. The kit includes the necessary springs, regulator adjustment components, and labeling required for a code-compliant installation. Technical accuracy is paramount when utilizing the F92-1008 LP kit to ensure the dual-stage gas valve maintains its rated BTU output and prevents soot accumulation or delayed ignition issues. This is a field-essential component for contractors servicing Copeland Comfort Control systems where fuel source flexibility is required.

Key Benefits:

  • Compatible with 36G, 36H, and 36J 2-stage gas valves for seamless field conversion.
  • Maintains accurate manifold pressure for consistent fuel delivery across multiple heating stages.
  • Constructed to OEM specifications to ensure mechanical integrity within the burner assembly.
  • Simplifies NAT to LP gas conversion without requiring a full valve replacement.
  • Includes specific hardware for two-stage regulation monitoring and adjustment.

Common Questions:

Can the F92-1008 be used on single-stage 36G valves?
No, this kit is specifically calibrated for the internal regulator mechanics of 2-stage White Rodgers valves. Using this on a single-stage valve will result in improper pressure regulation.

Does this kit include the orifice spuds?
This kit focuses on the gas valve regulator conversion components. You must verify if the specific burner orifices require independent replacement based on the appliance manufacturer's BTU requirements for propane.

What is the typical pressure setting for this kit?
Standard LP conversion usually targets 10.0" W.C. for high stage and approximately 3.5" to 4.5" W.C. for low stage, though you must always verify against the furnace rating plate.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Ask a Question
  • i got a new white rogers 36J-54 GAS VALVE I NEED TO CHANGE TO LP WILL THESE SPRIGS WORK

    We will need the model and serial numbers off the unit to check. Thanks