When you are troubleshooting a chiller or automation system that is throwing diagnostic codes related to pressure sensing, the York 025-41756-001 Transducer is the direct OEM replacement engineered for field reliability. This high-precision HVAC pressure sensor is designed to monitor critical system parameters with a standardized 0-200 PSI pressure range. It operates on a 5VDC excitation to provide a linear 0.5-4.5VDC output signal, making it fully compatible with York Millennium, YK, and YT chiller control centers. As a veteran technician knows, maintaining signal integrity is paramount; this York chiller part utilizes a robust construction to resist electrical noise and vibration common in mechanical rooms. Whether you are performing a seasonal overhaul or an emergency repair, utilizing an OEM York pressure transducer ensures the control board receives accurate data for head pressure control or oil pressure monitoring. This 025-41756-001 model is a critical industrial pressure transmitter for maintaining peak thermal efficiency and preventing high-pressure trips in commercial refrigeration circuits.

Key Benefits:
  • Precise Signal Conversion: Delivers a consistent 0.5-4.5VDC output for accurate 0-200# pressure tracking.
  • Direct OEM Compatibility: Engineered specifically for York HVAC equipment, ensuring "drop-in" installation without harness modifications.
  • Enhanced System Resilience: Built to withstand the harsh operating environments of commercial chillers and automation systems.
  • Linear Voltage Accuracy: Minimizes calibration drift to ensure the control board triggers safety cycles correctly.
Common Questions:

What are the symptoms of a failing York 025-41756-001 transducer?
Technicians typically see "out of range" faults on the control panel, hunting in the expansion valve, or erratic pressure readings that do not match mechanical manifold gauges.

Can this transducer be used for both oil and refrigerant pressure?
Yes, provided the system pressure remains within the 0-200 PSI range and the fluid is compatible with the sensor's stainless steel or brass internal elements.

What is the pinout for the 0.5-4.5VDC output?
While wiring varies by specific York model, most configurations follow the standard Red (Supply), Black (Ground), and Green/White (Signal) arrangement used in York control strings.