York 024-36074-000 Blower Motor

York 024-36074-000 Blower Motor

York

  • $903.41


The York S1-024-36074-000 is an OEM 3/4-1 HP ECM blower motor designed for high-efficiency air handlers and modular furnaces. As a veteran technician, you know that keeping a system running at peak performance requires exact HVAC replacement parts. This motor serves as the direct updated version for S1-024-31941-000, ensuring a seamless fit and proper communication with existing controls in models like the MV16CN21CC variable speed modular air handler. Because this is an unprogrammed blower motor without module, it allows you to retain your existing, functional control module while replacing only the failed mechanical component, saving your client significant overhead on the repair.

Operating on 115V, this high-efficiency ECM motor utilizes electronically commutated technology to provide variable speed operation, which is critical for maintaining precise airflow and static pressure balance. The brushless DC motor design reduces internal friction and heat, leading to greater reliability under industrial load conditions compared to standard PSC motors. When diagnosing a York blower motor failure, always verify that the control module is receiving the proper VDC signal before replacing the motor. This OEM York motor is built for heavy-duty cycling, ensuring the blower wheel maintains consistent RPM for optimal heat exchange and dehumidification.

Key Benefits
  • Direct OEM Replacement: Replaces S1-024-31941-000 to ensure factory-spec airflow and mounting alignment.
  • Cost-Effective Repair: Sold without the control module, allowing for a targeted motor-only replacement when the electronics are still viable.
  • Variable Speed Performance: Supports 3/4 to 1 HP applications with the efficiency of ECM technology, reducing energy consumption by up to 60% over traditional motors.
  • Quiet Operation: Precision-balanced rotor minimizes vibration and noise levels in residential and light commercial air handlers.
  • TEFC Enclosure: Designed to withstand the moisture and dust typically found in HVAC blower assemblies.
Common Questions

Is the control module included with this motor?
No, this is the motor portion only. You must utilize your existing module or purchase a separate, programmed control module compatible with the S1-024-36074-000.

Does this motor require a start capacitor?
No, ECM blower motors do not use traditional start or run capacitors found on PSC motors; the internal electronics (module) handle the motor's phase and torque.

Can this motor be used in place of a 3/4 HP motor?
Yes, this motor is rated for 3/4 to 1 HP applications, making it a versatile HVAC replacement part for York, Coleman, and Luxaire systems requiring those specifications.