York S1-024-35663-000 Fuse Link

York S1-024-35663-000 Fuse Link

York

  • $102.51


The York S1-024-35663-000 Fuse Link is a critical OEM HVAC safety component engineered for precise thermal protection in residential and commercial heating equipment. This surface mount auto limit switch serves as a high-limit safety, designed to open the electrical circuit when internal plenum or heat exchanger temperatures exceed safe operating parameters. Rated for 121°C (244°F), it provides a localized response to overheating conditions, effectively preventing equipment damage and ensuring the mechanical integrity of the furnace or air handler. As a genuine York replacement part, this fuse link maintains the exact specifications required by the original manufacturer, facilitating seamless integration and reliable thermal circuit interruption. Technicians should utilize this specific S1-024-35663-000 model to restore system safety protocols, ensuring the unit operates within its designated thermal envelope without the risk of nuisance tripping or safety bypass associated with non-spec alternatives.

Key Benefits for Technicians

  • OEM Precision: Guaranteed compatibility with York, Coleman, and Luxaire gas furnaces and air handling units.
  • Critical Safety Rating: Calibrated for a 244-degree Fahrenheit trip point to provide high-limit protection against blower failure or restricted airflow.
  • Durable Surface Mounting: Engineered for secure attachment to the heat exchanger shield or blower housing for accurate temperature sensing.
  • System Reliability: Restores factory-spec safety operations, reducing liability and ensuring long-term equipment protection.

Frequently Asked Questions

What causes a York fuse link to blow?
A blown fuse link typically indicates an overheating condition caused by restricted airflow, such as a dirty filter, blocked return air, or a failing blower motor. Always diagnose the cause of the high-limit trip before replacing the S1-024-35663-000.

Can I test the S1-024-35663-000 for continuity?
Yes. In a normal state, this thermal fuse link should show continuity (zero ohms). If the circuit is open, the fuse has tripped and must be replaced, as these are non-resettable safety devices.

Is this part compatible with other HVAC brands?
While primarily used in York equipment, this part is used across many Johnson Controls (JCI) brands, including Coleman and Luxaire. Always verify the part number against the unit’s data plate or service manual.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.