York S1-025-17620-014 Pressure Control

York S1-025-17620-014 Pressure Control

York

  • $54.82


The York S1-025-17620-014 Pressure Control is a critical safety component designed for high-pressure monitoring in HVACR systems. This OEM York refrigerant pressure switch features a specific 380 PSI open and 300 PSI close setting, acting as a reliable high-pressure cutout to protect the compressor from excessive discharge pressures. Engineered for field reliability, this high-pressure control switch ensures the system operates within safe mechanical limits, preventing catastrophic component failure during high-ambient conditions or airflow restrictions. When troubleshooting a system lockout, verify that the S1-025-17620-014 specs match the manufacturer's required setpoints for your specific condensing unit. This refrigerant pressure switch replacement is built for durability in demanding environments, providing precise pressure sensing and consistent electrical switching. Integrating this HVAC pressure sensor into your maintenance routine ensures the refrigeration cycle remains stabilized and secondary components are shielded from pressure spikes.

  • Precise Setpoints: Calibrated for 380 PSI cutout and 300 PSI cut-in to ensure accurate system protection.
  • OEM Compatibility: Genuine York replacement part ensures seamless fitment and electrical interface with residential and commercial units.
  • Heavy-Duty Construction: Built to withstand vibration and thermal cycling common in high-side refrigerant lines.
Common Questions:

What are the cut-in/cut-out specs for York S1-025-17620-014?
This control is designed to open the circuit when the system pressure reaches 380 PSI and close (reset) once the pressure drops back to 300 PSI.

How to replace a York high pressure control switch?
Ensure the system is powered down and refrigerant is managed according to local regulations; the switch installs onto the liquid or discharge line access port, typically via a flare or sweat connection depending on the specific manifold setup.

Is this switch manually or automatically reset?
The York S1-025-17620-014 is an automatic reset pressure control, meaning it will re-engage the circuit once the system pressure stabilizes at the 300 PSI close threshold.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.