York S1-025-26908-000 Rollout Control

York S1-025-26908-000 Rollout Control

York

  • $12.34


The York S1-025-26908-000 Rollout Control is a critical safety component designed for precise thermal monitoring within residential and commercial HVAC systems. As a fusible link limit control, this OEM part is engineered to detect abnormal high-temperature conditions—specifically flame rollout—and immediately break the electrical circuit to shut down the gas valve. This rapid response prevents hazardous overheating and potential equipment damage. Fabricated in the USA to strict York OEM specifications, it ensures seamless integration and reliable performance in demanding heating applications.

This fusible link rollout control is a direct replacement for York model P1UDD12N07601A and is compatible with a wide range of high-efficiency gas furnaces. Unlike manual reset switches, a fusible link rollout operates as a one-time safety device that must be replaced once the thermal link has reached its melting point. For veteran contractors, the S1-025-26908-000 provides the necessary peace of mind that the furnace rollout switch will perform exactly as specified during a combustion failure or blocked flue event.

Key Benefits:
  • OEM Compatibility: Precision-fit for York HVAC units, specifically the P1UDD12N07601A series.
  • High-Temperature Protection: Engineered to trip during flame rollout or excessive heat conditions in the burner compartment.
  • Reliable Construction: Manufactured in the USA, ensuring high-quality metallurgical standards for the link.
  • System Safety: Acts as a primary fail-safe to prevent fire hazards and manifold overheating.
  • Fast Installation: Standard mount design allows for quick field replacement by service technicians.
Common Questions:
  • Can I reset the York S1-025-26908-000 once it trips? No, this is a fusible link rollout control, not a manual reset switch. Once the internal link melts due to high heat, the part must be replaced to restore system operation.
  • How do I know if my rollout control is faulty? Use a multimeter to check for continuity. If the link is open (infinite resistance), it has likely reacted to a rollout event and requires replacement.
  • What causes a rollout switch to trip? Common causes include a cracked heat exchanger, blocked flue vent, or improper gas pressure leading to flames "rolling out" of the burner box.