York S1-025-41047-000 Temp Control
The York S1-025-41047-000 Temp Control is a precision-engineered SPST temp control switch designed for critical thermal monitoring in residential and light commercial HVAC applications. This HVAC temperature control switch is calibrated with fixed setpoints of 55Op 45Cl, meaning the contacts are programmed to open at 55°F and close at 45°F. As a York replacement part, it functions as a reliable safety or limit interface, frequently utilized for freeze protection or low-ambient cooling cycles. The Single Pole Single Throw configuration ensures a clean break in the electrical circuit when temperatures rise above the open setpoint, protecting system components from operating outside of designated thermal parameters. Utilizing this specific 55Op 45Cl switch ensures that your equipment maintains the tight 10-degree differential required for optimal performance in York, Coleman, and Luxaire air handlers or condensing units. This component is built for high-cycle durability, providing contractors with a dependable solution for field repairs and preventative maintenance tasks.
Key Benefits- Specifically calibrated 55°F open and 45°F close setpoints provide accurate thermal management for freeze protection.
- Standard SPST contact configuration allows for seamless integration into existing control circuits.
- Genuine OEM construction ensures physical and electrical compatibility with York-manufactured HVAC systems.
- Designed for rugged field use with a focus on long-term switching reliability in varying ambient conditions.
What is the primary function of the York S1-025-41047-000?
This switch acts as a thermal limit or freeze stat, typically used to interrupt a control circuit when temperatures reach 55°F and re-engage the circuit once the temperature drops to 45°F.
Is this temperature control compatible with other brands?
While designed as a York OEM part, it is compatible with equipment under the Johnson Controls umbrella, including Luxaire and Coleman, provided the technical specifications and mounting requirements match.
Does the orientation of the switch affect its 55Op 45Cl calibration?
No, the internal thermal disc operates based on temperature regardless of orientation, though it should be mounted in a location that accurately reflects the air or surface temperature being monitored.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.