York S1-025-43267-000 Gas Valve

York S1-025-43267-000 Gas Valve

York

  • $198.96


The York S1-025-43267-000 is an OEM-specified 24V NPT gas valve designed for precise fuel regulation in residential forced-air furnaces. Engineered as a robust furnace gas control, this component features a 1/2-inch flange configuration, facilitating a secure fit and streamlined installation within the manifold assembly. This model is the direct replacement for 36E29-101 (White-Rodgers), ensuring that port alignment and electrical terminations match the original equipment specifications for York, Luxaire, and Coleman units. The valve operates on a standard 24VAC solenoid circuit and is rated for multi-fuel versatility, supporting both natural gas and liquid propane (LP) configurations. Integrating this York gas valve replacement into your service routine ensures the burner assembly receives consistent pressure, which is critical for maintaining proper combustion profiles and heat exchanger integrity. For professional contractors, choosing these HVAC heating components eliminates the troubleshooting variables associated with universal aftermarket valves.

Key Benefits for Technicians
  • Direct OEM Compatibility: Specifically engineered to replace the 36E29-101 without necessitating manifold modifications.
  • Dual Fuel Capability: Suitable for natural gas and LP applications, allowing for broad field flexibility.
  • Precise Electrical Response: Features a high-reliability 24V solenoid for consistent opening and closing cycles.
  • Standardized Porting: The 1/2" flange design ensures a leak-resistant connection to existing gas lines.
Common Service Questions

Is the York S1-025-43267-000 a direct drop-in for the White-Rodgers 36E29-101?
Yes, this is the factory-authorized replacement part designed to match the footprint, electrical draw, and mechanical specifications of the original 36E29-101 series valves.

Can this valve be used for LP (Propane) conversions?
Yes, the S1-025-43267-000 is compatible with LP; however, it must be configured with the appropriate spring kit or conversion regulator as specified by the furnace manufacturer’s installation instructions.

What are the electrical requirements for this gas control?
This valve operates on a standard 24VAC, 60Hz circuit, typically powered through the furnace control board or a dedicated transformer.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question