York S1-025-45208-000 Expansion Valve

York S1-025-45208-000 Expansion Valve

York

  • $194.78


The York S1-025-45208-000 Expansion Valve is a precision-engineered thermostatic metering device designed for high-performance R410A expansion valve applications. Built with 3/8 x 3/8 TXV ODF connections, this component is the OEM standard for maintaining precise superheat levels within York, Luxaire, and Coleman evaporator coils. When performing a York TXV replacement, technicians rely on this part to prevent liquid slugging and ensure the compressor operates within its optimal thermal envelope. The S1-025-45208-000 compensates for varying load conditions, modulating refrigerant flow to maximize heat transfer efficiency across the indoor coil. As a critical HVAC metering device, it addresses common field issues such as evaporator icing or erratic suction pressures. Utilizing this specific OEM valve ensures that the system maintains its original SEER rating and pressure drop specifications, providing a reliable solution for residential and light commercial R-410A splits where aftermarket universal valves often fail to provide accurate modulation.

Key Benefits

  • Precision superheat regulation specifically calibrated for R-410A refrigerant cycles.
  • Durable 3/8 x 3/8 TXV brass body construction to withstand high-pressure environments.
  • Ensures consistent evaporator saturation for maximum cooling capacity.
  • Reduces mechanical stress on the compressor by preventing refrigerant floodback.
  • Exact OEM fitment eliminates the need for field modifications or line re-sizing.

Common Questions

How do I confirm if the S1-025-45208-000 is the correct valve for my unit?
Compatibility is determined by the model and serial number of the indoor coil or air handler. This valve is typically found in R-410A systems requiring 3/8-inch sweat connections.

What are the symptoms of a failing York 025-45208-000 TXV?
Common indicators include "hunting" (evidenced by fluctuating suction pressure), high superheat at the compressor inlet, or ice formation on the evaporator distributor lines despite a correct refrigerant charge.

Can this expansion valve be used in R-22 retrofits?
No, this valve is strictly designed for the pressure sets and lubricant requirements of R-410A systems. Using it with alternative refrigerants will result in improper metering and potential compressor damage.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question