Amana-Goodman 0130R00058 Switch

Amana-Goodman 0130R00058 Switch

Amana-Goodman

  • $18.88


The Amana-Goodman 0130R00058 Low Pressure Cutout Switch is a critical safety component designed for HVAC system protection against low refrigerant levels or compressor failure. This high-side mounted low pressure switch monitoring ensures that the refrigeration cycle is interrupted if pressure drops below the calibrated setpoint, preventing compressor overheating and oil starvation. As the direct OEM replacement for part number B1360719, this SPST (Single Pole Single Throw) switch provides a precise pressure setpoint cut-out to maintain heat pump and AC unit longevity. Engineered for use in residential and light commercial Goodman and Amana heat pumps, it features factory-terminated leads for easy field integration into the existing control circuit. Whether you are performing a liquid line repair or a full system overhaul, utilizing this copper HVAC pressure sensor ensures field reliability and maintains the integrity of the manufacturer's original safety specifications.

Key Benefits

  • OEM Compatibility: Exact replacement for Amana B1360719 and Goodman 0130R00058 ensures correct fit and electrical calibration.
  • Compressor Protection: Prevents catastrophic failure by monitoring for low refrigerant pressure conditions and cycling the contactor off.
  • Durable Construction: Built with high-grade copper and hermetically sealed contacts for reliable performance in harsh HVAC environments.
  • Standardized Wiring: Equipped with standard lead lengths for fast connection to the low voltage control board.

Common Questions

What is the difference between 0130R00058 and B1360719?
They are technically identical; the 0130R00058 is the current manufacturer part number, serving as the direct functional and physical replacement for the obsolete B1360719.

Will this work with R-410A systems?
Yes, this switch is designed for high-pressure refrigerants and is calibrated specifically for the low-side operating parameters found in modern R-410A heat pump systems.

Is this switch auto-reset or manual-reset?
This model is typically an auto-reset pressure switch, which means it will close the circuit once the system pressure rises above the cut-in threshold, though diagnostic verification of the cause of the trip is recommended.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.