Danfoss 060L112566 Temperature Control

Danfoss 060L112566 Temperature Control

  • $129.54


The Danfoss 060L112566 is a professional-grade KP81 Temperature Control engineered for high-demand industrial regulation and monitoring systems. Featuring a Single Pole Double Throw (SPDT) contact system, this unit functions as a high-limit cut-out or temperature-operated electric circuit breaker. It is capable of directly controlling single-phase AC motors up to 2 kW, making it a rugged choice for boiler applications and district heating systems. With a functional range of 176°F to 302°F (80°C to 150°C), the 060L112566 provides precise thermal management using a remote bulb sensor and a 2-meter (approx. 80-inch) capillary tube for flexible installation. The IP30 enclosure ensures protection against solid objects in industrial environments, while the automatic reset function maintains system continuity without manual intervention. Built for reliability, the silver-plated cadmium oxide contacts offer high-load endurance, ensuring the HVAC temperature switch stays responsive under high-cycle conditions.

Key Benefits:
  • Versatile Application: Ideal for industrial refrigeration, boiler controls, and high-temperature alarms.
  • Direct Motor Control: Rated to handle 2 kW AC motors directly, reducing the need for additional contactors.
  • Precise Sensing: High-accuracy capillary temperature controller with a remote bulb designed for sensing away from the switch body.
  • Industrial Durability: Robust IP30-rated housing with a compact footprint, suitable for standard HVACR control panels.
  • Flexible Differential: Adjustable differential settings (approx. 12.6°F to 36°F) allow for fine-tuned thermal cycling.
Common Questions:

What is the maximum operating temperature for the sensor?
The sensor is designed for a range of 176°F to 302°F (80°C to 150°C), with a maximum bulb temperature limit of approximately 392°F (200°C) to prevent thermal damage.

Can this be used for both heating and cooling applications?
Yes, because it features an SPDT switch, it can be wired to break the circuit on temperature rise (heating) or make the circuit on temperature rise (cooling), depending on your terminal configuration.

Does this unit require a manual reset after a trip?
No, the 060L112566 model features an automatic reset, which restores the electrical circuit once the temperature falls below the setpoint minus the differential.