Amana-Goodman 0130M00595S Transformer

Amana-Goodman 0130M00595S Transformer

Amana-Goodman

  • $58.56


The Amana-Goodman 0130M00595S Transformer is a heavy-duty 75VA control transformer engineered for high-voltage HVAC systems requiring a reliable step-down from 480V to 24V. This OEM component serves as the direct replacement for 0130M00145, ensuring seamless integration into existing circuit boards and contactor setups without the need for field modifications. Designed for industrial-grade durability, this 480V step-down transformer manages the 24V secondary circuit load required for thermostats, gas valves, and ignition modules. It features pre-tinned lead wires and a standard mounting footprint to streamline HVAC transformer replacement in the field. When troubleshooting commercial rooftop units or high-voltage air handlers, the 0130M00595S provides the necessary VA capacity to prevent voltage drops across the control circuit, maintaining consistent amperage for heavy-duty contactors and auxiliary relays. This genuine Goodman replacement part ensures electrical compliance and protects sensitive low-voltage electronics from fluctuations in the primary line.

Key Benefits and Specifications:
  • Direct OEM Replacement: Replaces legacy part number 0130M00145 with exact physical and electrical specifications.
  • 75VA Power Rating: High VA capacity supports complex control circuits and multiple 24V peripherals.
  • Voltage Conversion: Accurately steps down 480V primary voltage to 24V secondary output.
  • Rugged Construction: Built to withstand the high-temperature environments typical of commercial HVAC cabinets.
  • Simplified Installation: Standard frame size and lead wire configuration for fast technical swap-outs.
Common Questions:

Is the 0130M00595S compatible with 208/240V systems?
No, this transformer is specifically designed for 480V primary input. Using it on lower voltage lines will result in insufficient secondary output.

Can I use this to replace a 40VA or 50VA transformer?
Yes, this 75VA unit can replace lower VA rated transformers as long as the primary/secondary voltages match, providing more headroom for the control circuit.

Does this include a built-in fuse or circuit breaker?
This model utilizes standard internal thermal protection; however, it is standard practice to verify the secondary circuit fuse on the control board during installation.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.