Amana-Goodman 0171M00001S Inducer Assembly

Amana-Goodman 0171M00001S Inducer Assembly

Amana-Goodman

  • $193.92


Ensure reliable combustion and exhaust cycles with the Amana-Goodman 0171M00001S Inducer Assembly. This OEM Goodman furnace part is a critical component for maintaining proper static pressure and venting flue gases in 92% and 96% AFUE high-efficiency condensing furnaces. Engineered for a 120V, 60Hz power supply, this 1/20 HP draft inducer blower motor operates at 3000 RPM with a 2.80 Amp draw, providing the consistent airflow required to prove the pressure switch and initiate the ignition sequence.

Designed as a direct replacement inducer assembly for GCSS96 and GMSS92 series furnaces, this unit features a durable housing and a precision-balanced wheel to minimize vibration and bearing wear. For technicians servicing legacy units manufactured before August 2005, note that modern replacement 0171M00001S units may require a separate drain elbow kit for horizontal-left installations. Utilizing genuine Amana replacement parts ensures factory-spec performance and long-term reliability in demanding residential heating applications.

Key Benefits

  • Direct OEM Match: Guarantees precise fitment and compatibility with Goodman, Amana, and Daikin induced-draft furnaces.
  • High-Speed Performance: 3000 RPM motor ensures the vent blower generates sufficient negative pressure to clear the heat exchanger.
  • Simplified Installation: Includes pre-installed motor, wheel, and housing to reduce bench time during HVAC furnace repair.
  • Thermally Protected: Class B insulation and thermal protection prevent motor burnout during restricted vent conditions.

Common Questions

Does this assembly include the mounting gasket?
Yes, this 0171M00001S assembly typically includes the required mounting gasket and specialized hardware to maintain a gas-tight seal against the collector box.

Will this fix a furnace that is not igniting but the inducer is running?
While the motor may spin, a failing wheel or blocked flue can prevent the pressure switch from closing. If the motor is noisy or failing to reach 3000 RPM, replacing the inducer assembly is often necessary to restore the sequence of operation.

Can I use this for a horizontal furnace installation?
Yes, but technicians should verify if the legacy drain port configuration requires additional tubing or a drain elbow kit (Part # 20171802S) for condensate management in older horizontal-left models.