Bard HVAC 9022-095 Primary

Bard HVAC 9022-095 Primary

Bard HVAC

  • $288.04


The Bard 9022-095 Genisys Primary Control with pre-purge functionality is a critical component for maintaining precise combustion cycles in high-performance oil-fired heating systems. Designed to serve as a direct replacement for Beckett Genisys 7505P series controls, this 120V AC unit manages the oil burner’s ignition, flame sensing, and motor control with industrial-grade reliability. The integrated pre-purge timing ensures the combustion chamber is cleared of residual vapors before ignition, reducing soot buildup and preventing delayed ignition issues. By monitoring the cadmium sulfide (cad cell) flame sensor, the 9022-095 provides rapid safety shutdowns if a flame failure is detected. This control is engineered for interrupted or intermittent duty and features a restricted lockout mode to prevent repetitive resetting of a fouled system. For technicians servicing Bard wall-mount units or standard oil furnaces, this primary provides the diagnostic LED indicators necessary for rapid field troubleshooting and consistent BTU output regulation.

Key Benefits for Technicians
  • Pre-Purge Cycle: Clears the heat exchanger of unburnt oil vapors to ensure a clean, stable light-off.
  • Cross-Brand Compatibility: Serves as a reliable aftermarket replacement for various Beckett and Bard oil primary controls.
  • Diagnostic LED Logic: Provides immediate visual feedback on flame status and system lockout codes to minimize downtime.
  • Restricted Lockout Safety: Enhances mechanical longevity by preventing the burner from cycling under unsafe combustion conditions.
  • Solid-State Reliability: Resistant to the vibration and thermal cycling common in HVACR equipment environments.
Common Questions

Can the pre-purge timing be adjusted on the 9022-095?
Most Bard 9022-095 units come with factory-set timings. Always verify the specific timing sequence on the component label to match the heat exchanger requirements.

What causes a lockout on this primary control?
Lockouts typically occur due to cad cell failure, a clogged oil nozzle, or contaminated fuel preventing a consistent flame signal during the trial for ignition.

Is this control compatible with 24V ignition systems?
No, this is a 120V AC primary control. Ensure your line voltage and transformer configuration match the technical specifications of the 9022-095 before installation.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.