Weil McLain 592-800-010 Bottom Elastomer Seal

Burnham Boiler 105133-02 2 Pipe Assembly

Burnham Boiler

  • $470.32


The Burnham Boiler 105133-02 2 Pipe PVC 3x4 Assembly is the OEM two-pipe PVC venting assembly sold under the Burnham part number 105133-02. A two-pipe system is the arrangement used on direct vent boilers: one pipe carries combustion air in from outdoors and the second carries the flue gases out, so the burner runs on outdoor air and never uses air from the room. The 3x4 designation tells you the assembly is built around the 3-inch and 4-inch PVC pipe sizes of that arrangement, which is why it is a separate number from its siblings.

Burnham issues this assembly in matched sizes under the same base number. The 105133-01 is the 2 Pipe PVC 3x3 assembly and the 105133-03 is the 2 PVC Pipe 4x4 assembly, so the dash number carries the pipe size. Choosing by size is not a detail to skip: a condensing boiler's vent and air pipes are sized for a reason, because the flow through them has to match what the combustion blower can move. A wrong-size connection raises the resistance on the blower, trips the air pressure switch or leaves the boiler struggling at high fire. A boiler also puts out condensate with its exhaust, so the vent side has to slope back toward the boiler and every joint has to be tight and sealed.

Installation should follow the boiler's installation manual for approved PVC material, primer and cement, maximum pipe length and number of fittings, because those limits are set by the manufacturer for each model. Dry-fit the assembly, support the pipe so its own load never hangs on the boiler connection, glue the joints with the correct primer and cement, and give the cement time to cure before the boiler runs. Keep the intake terminated where it will not draw in exhaust, snow or debris. After the boiler is running, check the draft, watch for leaks at the joints and confirm the combustion readings are in range. Confirm the boiler model and the vent and air pipe sizes in its manual before ordering so the 3x4 arrangement matches what the boiler requires.

Key Benefits

  • Two-Pipe Direct Vent: Provides separate combustion air and flue gas pipes for direct vent operation.
  • 3x4 Pipe Sizing: Built around the 3-inch and 4-inch PVC sizes, distinct from the 105133-01 (3x3) and the 105133-03 (4x4).
  • OEM Burnham Assembly: A factory PVC assembly keeps the vent and air sizing the boiler was approved with.
  • Protects Blower Performance: Correct sizing keeps resistance in range so the combustion blower and air pressure switch operate normally.

Common Questions

  • What does 3x4 mean? It names the 3-inch and 4-inch PVC pipe sizes of the two-pipe assembly. The 105133-01 is 3x3 and the 105133-03 is 4x4.
  • Why use two pipes? Direct vent boilers bring combustion air in through one pipe and send flue gases out through the other, so the burner uses outdoor air.
  • What should I follow when installing it? The boiler's installation manual for approved PVC, primer, cement and maximum vent length.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.